Energy Saving Features
NOTE
: The energy consumption will be increased by maintenance issues for example: - blocked condenser, poor door seal, increased ambient temperature and high
usage.
The refrigeration systems have a solenoid valve fitted in the discharge line between the condenser and the drier. The solenoid valve is controlled by the temperature
controller along with the condensing unit and condenser fan. The reason it is fitted is to reduce the power consumption each time the compressor starts. This is achieved
by reducing the refrigerant migration into the evaporator therefore reducing the amperage when the compressor starts.
The ECM evaporator fan motor has a low heat output motor and it should be noted that when the power is switched off stops rotating straight away.
Single Section Plug Box
Discharge Line
Solenoid Valve
Position
Hot Gas
Solenoid Valve
Position
Single Section Plug Box
Discharge Line
Solenoid Valve
Position
Hot Gas
Solenoid Valve
Position
13