Eprem Controller Default Parameter Values 

 

Title Parameter 

Definitions 

Min 

MAX 

Default 

Dim 

HT 

HT 

No DS 

LT 

GAS 

LT ‘G’ 

No DS 

LT 

ELE 

LT ‘E’ 

No DS 

MT  

GAS 

MT ‘G’ 
No DS 

Fish Wine  Heated 

Scale 

Readout 

scale 

ºC 

ºF 

 

ºC flag 2  2 2 2 2 2 2 2 2 

2 2 

Min Temp 1 

Minimum setpoint  [ I ] 

-40 

Max 

Temp 1 

ºC 

1 -21 -21 -21 -21  -2  -2  -1 8  83 

Max Temp 1 

Maximum setpoint  [ I ] 

Min 

Temp 1 

100 

ºC 

3 -19 -19 -19 -19  0  0  1 12  91 

Temp. Set 1 

Setpoint [ I ] 

Min 

Temp 1 

Max 

Temp 1 

ºC 

2 -19 -19 -19 -19  -1  -1  0 10  87 

Temp. Hyst 1 

Thermostat hysteresis [ I ] 

-10 

10 

ºC 

-3 

Compr. 

Rest 

Minimum 

compressor 

rest 

time 

0  30  2 min 2  2 2 2 2 2 2 2 2 

2 0 

Comp. 

ON 

Compressor 

run 

with 

T1 

failure 

0  30  7 min 7  7 7 7 7 7 7 7 7 

7 7 

Comp. 

OFF 

Compressor 

stop 

with 

T1 

failure 

0  30  3 min 3  3 3 3 3 3 3 3 3 

3 3 

Defrost/Day 

Defrost 

frequency 

24h 

0  24  2 

1/24h 

2  2 4 4 4 4 4 4 0 

4 0 

Defr. 

End 

Tp 

Defrost 

end 

temperature 

-40 

40  20  ºC  20  20 20 20 20 20 20 20 20 

20 20 

Defr. 

End 

Tm 

Maximum 

defrost 

duration 

120  20  min  20  20 20 20 20 20 20 20 20 

20 20 

Defr. Type 

Defrost type 

OFF/ ELE/ GAS 

OFF 

flag 

OFF 

OFF 

GAS 

GAS 

ELE 

ELE 

GAS 

GAS 

OFF 

OFF 

OFF 

Drain 

Time 

Drain 

down 

time 

0  30  2 min 2  2 2 2 2 2 2 2 2 

2 2 

Def. 

Display 

Defrost 

display 

control 

60  10  min  10  10 10 10 10 10 10 10 10 

10 10 

Fan in Def 

Fan activity during defrost 

No  

Yes 

Yes 

flag 

Yes 

Yes 

No 

No 

No 

No 

No 

No 

Yes 

Yes 

Yes 

Fan 

Dly. 

Tp 

Fan 

re-start 

delay 

temperature 

-40  40  0  ºC  0  0 0 0 0 0 0 0 0 

0 0 

Fan 

Dly. 

Tm 

Evaporator 

fan 

maximum 

time-out 

0  120  3 min 3  3 3 3 3 3 3 3 3 

3 3 

Fan Tm Con 

Evaporator fan timed control 

No 

Yes 

Yes 

flag 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

No 

Yes 

No 

Fan 

Stop 

Dly 

Fan 

stop 

delay 

180  15 sec. 15  15 15 15 15 15 15 15 15 

15 15 

Fan 

Off 

Tm 

Timed 

fan 

stop 

0  30  2 min 2  2 3 3 3 3 3 3 2 

2 2 

Fan 

Run 

Tm 

Timed 

fan 

run 

0  30  1 min 1  1 1 1 1 1 1 1 1 

1 1 

Lo 

Alarm 

dt 

Low 

alarm 

differential 

-12 

0  -5  ºC  -5  -5 -5 -5 -5 -5 -5 -5 -5 

-5 -5 

Hi 

Alarm 

dt 

High 

alarm 

differential 

0  12  5  ºC  5  5 5 5 5 5 5 5 5 

5 5 

Alarm 

Delay 

Alarm 

temperature 

delay 

120  90  min  90  90 90 90 90 90 90 90 90 

90 90 

 

9

 

Содержание EPREM 1/2H

Страница 1: ...EPREM CABINET COUNTER ISO 14001 ISO 9001 ...

Страница 2: ...tore and dispose of it in such a way as to prevent its escape into the environment harm to human health and to ensure the compliance with the environmental law Guidance is available from the Environment Agency on how to comply with the waste management duty of care 3 The following waste must be stored of separately from other wastes as they are hazardous to the environment refrigerants polyurethan...

Страница 3: ...n and exceed the Montreal protocol using zero ODP refrigerants and insulation with Hydrocarbon refrigerant as an option There are 3 temperature options exceeding Climate Class 5 operation up to 43 c ambient Temperature is controlled by a LAE microprocessor control with digital temperature display The standard refrigeration system is integral with an air cooled condensing unit with the refrigerant ...

Страница 4: ...s 1 and 2 to view temperatures Text Air Evaporator Condenser Food Tlo Thi Text Tlo indicates the lowest temperature the machine has achieved Thi indicates the highest temperature the machine has achieved This information is useful when checking on the possible cause of iced up evaporators If the relevant probe is not fitted display shows Press button 4 to exit to User Main Menu Basic User Adjustme...

Страница 5: ...will then extinguish and the LED display will show the temperature measured by Probe 1 T1 the internal air temperature probe The function LED s will also illuminate to show which output relays are energised Therefore if the measured temperature is not within the pre set temperature range the controller will activate the condensing or heating system All timings i e defrost intervals will be taken f...

Страница 6: ...FR 24H defrost frequency 24 H determines how many defrost in a 24 hour period The cabinet will perform at least 1 defrost per day and if the setting is 3 it has the potential to initiate up to 2 additional defrost whilst in the economy mode Should the cabinet experience constant usage the controller will switch automatically to the second parameter settings which could under circumstances of heavy...

Страница 7: ...lay will continue to flash throughout this alarm The LED display will show the internal air temperature and the function icons If the temperature has not returned to within the operating limits after one hour the alarm will resound for one minute This process will continue until automatically cancelled by the system returning to its normal operating temperatures Low Temperature Alarm This alarm oc...

Страница 8: ...porator Fan Relay press button 2 Relay 2 will energise To test relay 3 Defrost System Relay press button 3 Relay 3 will energise To test all three relay outputs press buttons 1 2 and 3 together All three relays will energise To exit the Output Relay Test Menu and return to the User Main Menu press button 4 If no further buttons are pressed for one minute the controller will revert to the normal op...

Страница 9: ...uirement or to overcome an operating problem If any parameters require adjusting for example if the standard number of defrosts in the economy or heavy duty settings 2 requires to be increased the following procedure should be followed From Service Main Menu depress button 2 Model Use button 2 to scroll through to the required parameter heading If the require parameter is missed use button 1 to sc...

Страница 10: ... 20 20 20 20 20 20 Defr End Tm Maximum defrost duration 1 120 20 min 20 20 20 20 20 20 20 20 20 20 20 Defr Type Defrost type OFF ELE GAS OFF flag OFF OFF GAS GAS ELE ELE GAS GAS OFF OFF OFF Drain Time Drain down time 0 30 2 min 2 2 2 2 2 2 2 2 2 2 2 Def Display Defrost display control 0 60 10 min 10 10 10 10 10 10 10 10 10 10 10 Fan in Def Fan activity during defrost No Yes Yes flag Yes Yes No No ...

Страница 11: ... Defrost Day 2 Defrost Frequency 24h in mode 2 0 24 4 1 24h 4 4 4 4 4 4 4 4 4 4 4 Door Switch Door switch enabling NO YES YES flag YES NO YES NO YES NO YES NO YES YES YES Door Stop Compressor stop delay from door opening 0 30 1 min 1 1 1 1 1 1 1 1 1 1 1 Door Alarm Door alarm delay 0 30 8 min 8 8 8 8 8 8 8 8 8 8 8 Air o s T1 air probe offset 12 12 0 ºC 0 0 0 0 0 0 0 0 0 0 0 Evap Probe T2 evap probe...

Страница 12: ... 0 042 Timed Off Cycle 230 1 50 10 0 indicative 13 Amp EPREM S 450L R404A 300 grms SC15CLX 3 0m x 0 042 Electric 230 1 50 6 2 indicative 13 Amp EPREM G 550H R134A 350 grms FR7 5GX 3 0m x 0 042 Timed Off Cycle 230 1 50 4 1 indicative 13 Amp EPREM G 550L R404A 325grms SC21CLX 3 0m x 0 054 Electric 230 1 50 6 8 indicative 13 amp EPREM S 1000H R134A 450grms GP16TB 3 0m x 0 054 Timed Off Cycle 230 1 50...

Страница 13: ...Amp EPREM B 600H R290 160 grms TL5CNX 2 8m x 0 042 Timed Off Cycle 230 1 50 3 8 tested 13 Amp EPREM B 600L R290 150 grms SC15CNX 3 0m x 0 047 Hot Gas 230 1 50 13 4 tested 13 Amp Technical Data Pro R290 Counter Power Consumption Model Gas Gas Charge Compressor Capillary Defrost Type Voltage kW 48hrs Fuse Rating EPREM 1 2H R290 160 grms TL5CNX 3m X 0 042 Timed Off Cycle 230 50 1 3 2 tested 13 Amp EP...

Страница 14: ...unit and condenser fan The reason it is fitted is to reduce the power consumption each time the compressor starts This is achieved by reducing the refrigerant migration into the evaporator therefore reducing the amperage when the compressor starts The ECM evaporator fan motor has a low heat output motor and it should be noted that when the power is switched off stops rotating straight away Single ...

Страница 15: ...Wiring Diagrams 14 ...

Страница 16: ...15 ...

Страница 17: ...16 ...

Страница 18: ...17 ...

Страница 19: ...18 ...

Страница 20: ...cial fosterfrance com Germany Foster Refrigerator Gmbh Tel 49 781 990 7840 Fax 49 781 990 7844 Email info foster gmbh de Foster Refrigerator Oldmedow Road Kings Lynn Norfolk PE30 4JU Tel 01553 691122 Fax 01553 691447 Website www fosterrefrigerator co uk Email sales foster uk com a Division of ITW UK Ltd EPREM SM 11 08 19 ...

Отзывы: