background image

WARNING

Thank you for purchasing a Foster Range Hood. 

Please read all the instructions in this manual before 

installing the appliance.

Save these instructions for future reference.

Only use this appliance as an exhaust ventilation system for the removal of 

cooking vapors. 

DO NOT

 use to expel flammable substances or any other 

materials or vapors. 

The installation procedures in this manual are intended for qualified  instal-

lers, service technicians or persons with similar qualified background. 

DO NOT

 attempt to install this appliance yourself.

Ensure that electrical power is turned off at source before commencing in-

stallation.    All  electrical  wiring  must  be  properly  installed,  insulated  and 

grounded and conform to all applicable codes and standards.

Make sure all existing duct work is clean of grease build up, or duct work 

should be replaced, if necessary, to avoid the possibility of a grease fire.  

Check  all  joints  on  ductwork  to  ensure  proper  connection  and  all  joints 

should be properly taped.  Be careful when cutting through ceilings or walls 

not to damage any hidden pipes or electrical wiring.  Ensure your kitchen has 

sufficient air return vents to replace the exhausted air.

Fan ducts should always be vented to the outside of your home and never 

into spaces within walls, ceilings, lofts or attics.  Only use rigid, smooth steel 

for ducting.  The exhaust point of the blower requires a 6” round  connec-

tion.

2

Содержание 2459 910

Страница 1: ...NT SUBI AUCUN DOMMAGE PENDANT LE TRANSPORT SHIPPING DAMAGE MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT DOMMAGES DE TRANSPORT DOIVENT TRE NOTIFI S DANS LES 5 JOURS SUIVANT LA R CEPTION INSTALLATION INSTR...

Страница 2: ...ommencing in stallation All electrical wiring must be properly installed insulated and grounded and conform to all applicable codes and standards Make sure all existing duct work is clean of grease bu...

Страница 3: ...DUCTING 4 ELECTRICAL 5 Electrical Supply 5 INSTALLATION 6 Before the installation 6 Panels opening 6 Installation 6 OPERATING PROCEDURES 8 General Advice 8 WORKING 9 MAINTENANCE 11 Cleaning the Filte...

Страница 4: ...of the ducting cau se severe air turbulence and will signifi cantly reduce the efficiency of any hood THIS TYPE OF DUCTING WILL REDUCE EFFICIENCY BY 50 Vent hoods may interrupt the proper flow of exha...

Страница 5: ...d venting hook ups must be in place before commencing installa tion of the hood fan ELECTRICAL WARNING All electrical work must be performed by a qualified electrician Please ensure that the appropria...

Страница 6: ...lease check that all compo nents are not damaged in such a case contact your retailer and do not carry out installation INSTALLATION Fit a false ceiling with an opening that has the following dimensio...

Страница 7: ...hreaded bars provided into the plugs as shown in case of a larger gap between the hood and the ceiling you need to use longer th readed bars Connect the power supply into the metal box placed inside t...

Страница 8: ...te Heat oil slowly in an appropriately sized pot covering the en tire burner to reduce the risk of boiling over and burning In the event of a range top grease fire ob serve the following Switch OFF th...

Страница 9: ...RESS THE KEY LIGHT ON AT 100 LIGHT ON AT 100 SHORTLY PRESS THE KEY LIGHT OFF LIGHT ON AT 100 CONTINOUSLY PRESS THE KEY BRIGHTNESS REDUCTION WORKING RELEASING THE KEY DURING REDUCTION OR INCREASE LIGHT...

Страница 10: ...odes Emergency button In the event that the radio control does not work use the emergency button to switch the appliance off After any necessary repai rs have been performed reset the emergency button...

Страница 11: ...These can be ordered from the supplier of your range hood Cleaning the Hood Cleaning of the internal parts should be done with a clean damp not excessively wet cloth together with regular household de...

Страница 12: ...fixture using a soft instrument such as a toothpick Steel in struments will scratch the surface Replace the appropriate bulb Check parts brochure or specification sheets on our website Wipe both sides...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...directly during use and or maintenance and which may be subject to wear The formation of rust and stains on the steel due to the use of unsuitable cleaning agents Any functional defect indicated by t...

Страница 16: ...e by FOSTER with the desire of offering the best service available FOSTER is not liable for any damages direct or indirect caused to people objects and pets for failure to follow all the instructions...

Отзывы: