quality.
D. The 485 AB lines of DVR can not connected with other 485 output equipments paralleled.
E. The voltage between the AB lines of the decoder must be less than 5V.
4
、
Front equipment grounding note
Bad grounding can lead to the burnout of the chip.
5
、
Alarm input type unlimited
The DVR alarm output port is constant opening type.
(1) (2)
(3) (4)
(1) alarm input 1
(2) grounding (3)
alarm
output1
(4)
RS485
parameter meaning
G grounding
C1
、
NO1
Alarm output interface(constant open type)
A
、
B
485communication interface which is connected with the recording
control equipments such as the decoder
2.6.1 Alarm input port specification
1 channels alarm input. Alarm input type unlimited.
The grounding and the com port of the alarm sensor are parallel (The alarm sensor is external power supply) .
The grounding of the alarm and the DVR should be shared.
The NC port of the alarm sensor must be connected with the DVR alarm input port.
The grounding of the power supply and the alarm sensor must be shared when used in external power supply.