8. Troubleshooting
Object
0x2000
has
value
0x8000
.
Other sensor error.
u
Clean the optical connectors. See
Cleaning E-2000/APC Connections,
page 68
.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Check the signal quality. See
Troubleshooting Signal Quality,
page 61
Object
0x2000
has
value
0x8001
.
Channel not
available on this
measurement
device.
u
Check if the channel is physically
present.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
Object
0x2000
has
value
0x8002
.
No sensor detected
on this channel.
u
Clean the optical connectors. See
Cleaning E-2000/APC Connections,
page 68
.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Check the signal quality. See
Troubleshooting Signal Quality,
page 61
Object
0x2000
has
value
0x8003
.
Sensor temporarily
unavailable for
measurement (light
source regulates
power).
u
Wait until regulation is complete.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Check the signal quality. See
Troubleshooting Signal Quality,
page 61
Object
0x2000
has
value
0x8004
.
Sensor or channel
error.
u
Clean the optical connectors. See
Cleaning E-2000/APC Connections,
page 68
.
u
Reboot the Blackbird OECD. Turn the
power supply off and on.
u
Check the signal quality. See
Troubleshooting Signal Quality,
page 61
© fos4X 2020
MDE0835_4-10_1.3.x_5.0_Blackbird
OECD_(6CH, CNO)-en-us
65 / 80