![Fortress Technologies PURE VIEW FULL GLASS PANEL AL13 HOME Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/fortress-technologies/pure-view-full-glass-panel-al13-home/pure-view-full-glass-panel-al13-home_installation-instructions-manual_2322445031.webp)
31
PURE VIEW: Al
13
HOME FULL GLASS PANEL INSTALLATION
ANGLE BRACKET: CUTTING DOWN TOP & BOTTOM RAILS
•
Reference pages 11 - 13 for Rail Cutting steps.
ANGLE BRACKET: FULL GLASS PANEL INSTALLATION
•
Reference Full Glass Panel installation instructions on
pages 13 - 16.
ANGLE BRACKET: ROUND & FLAT ACCENT TOP RAIL (ATR)
•
Reference page 17-19 for Proud Post ATR steps.
•
Reference page 20-24 for OTP ATR steps.
ANGLE BRACKET: ROUND & FLAT ATR MITER SPLICE
Step 1:
ATR Angle Splice (Proud Post)
1. Use 3/32” [2.5mm] hex wrench to tighten set screw
and lock Angle Bracket at 45
o
degree position.
As shown in Fig. 1, 2.
2. Place Angle Splice on top of ATR butting up the end
face of the splice to the face of the 3” [76mm] post.
As shown in Fig 3, 4.
3. A Rubber Mallet might need to be used to install. If using a
Rubber Mallet, use a cloth to protect the ATR from damage.
4. Secure Angle Splice with two #6-20 x 1/2” [12.5mm]
self-drilling screws.
Note:
• Angle Splice only work if brackets are angled at the 45
o
degree setting.