MODE 1
DEFAULT
MODE 2
MODE 3
MODE 4
MODE 5
MODE 6
15
Smart Arming
Smart Doorlock
Smart Lock pulse
Disable
(Unlock signal)
Automatically LO CK
and rearm alarm if
door(s) are not opened
after 30 seconds.
Automatic Lock when
starter kill arms.
Lock pulse only when its
Unlock
—
—
16
Cold Start Timer
3 hours at -5
o
c/Runtime
1.5 hours at -5
o
c/
Runtime
3 hours at -5
o
c/5 minutes
1.5 hours at -5
o
c/5
minutes
Cold time OFF
—
17
Domelight Delay
Disable
Enable Ignore door
trigger (dome light)
when arming or
Remote-starting
—
—
—
—
18
Diesel Mode
Disable
Enable (20 seconds)
Delay between Ignition
power up and Starter
(crank).
Enable (10 seconds)
Delay between Ignition
power up and Starter
(crank).
Enable
No delay between
Ignition power up and
Starter (crank).
—
—
19
Turbo timer
Disable
Run 2 minutes.
Run 4 minutes.
—
—
—
20
Engine supervision:
-Tachless - -analog
tach- -Tach Data-
Link-
Tachless on crank and
supervision Tach Data-
Link or analogic after
Tachless only.
(
vehicles with
automatic transmission
only)
Analog Tach learning
(see p.4 for programming)
Start (crank) 8 sec
on tachless. (
vehicles with automatic
transmission only)
Start (crank) 8 sec+
Supervision by
Data-Link Tach (Data
interface required)
Tach Data-Link
only (Data interface
required)
21
Start Attempts
2
1
3
—
—
—
22
—
—
—
—
—
—
—
23
Master RESET
RESET all programming
options by default.
(Retains already
programmed remote.)
—
—
—
—
—
24
Special
application
Disable
Application 1
Application 2
Application 3
—
—
25
Auxiliary 1 Output
TRUNK --> LOCK
0.5 seconds &
disarm alarm
0.5 seconds
10 sec latch or
until a button is pressed.
20 sec latch or
until a button is pressed.
30 sec latch or
until a button is
pressed.
Latch until shutdown
26
Hybrid mode
Gas / Diesel vehicle
Hybrid vehicle
—
—
—
—
27
Auxiliary 2 Out-
putTRUNK-->
UNLOCK
0.5 seconds &
disarm alarm
0.5 seconds
10 sec latch or until a
button is pressed.
20 sec latch or until a
button is pressed.
30 sec latch or until a
button is pressed.
—
28
Manual transmission
Neutral safety switch
Special Application
No application
Enable (see p.4)
For manual transmission vehicles equipped with neutral safety switch. DO NOT CUT THE LOOP.
Connect the auxiliary IN (Purple/White) to the neutral safety switch of the vehicle.
29
Alarm Duration
30 seconds
60 seconds
120 seconds
—
—
—
30
Valet code
Ignition ON
Valet button x3 times.
Ignition ON
Valet button x3 times
and x1 times 3
seconds.
Ignition ON
Valet button x4 times
and x1 times 3 seconds.
Ignition ON
Valet button x5 times
and x1 times 3 seconds.
Ignition ON
Valet button x6
times and x1 times 3
seconds.
Ignition ON
Valet button x7 times
and x1 times 3 sec.
31
Special application
Programmable
output (+)
No special application
Priority on function 2
Special application - Function 2 (all option)
not available.
—
—
Enable at ground out,
disable with vehicle
ignition off
White wire (5th relays):
Trunk )
White wire (5th relays):
(+)Parking light output
32
Configuration
Dk.Blue (Pin17)
Yellow/Red (Pin19)
wire
Dk.Blue (Ground out,
Pin17): Shut-down 1
second after remote
start run time.
------------------
Yellow/Red (Pin19)=Arm
Dk.Blue (Ground out,
Pin17): Shut-down 3
seconds after remote
start run time.
Yellow/Red (Pin19) (Arm):
Shutdown after
—
—
—
33 Manual transmission
function
Activated by the remote
starter remote.
See page 4.
Automatically activated
by hand-brake and Foot
Brake.
Manual sequence
completed by locking the
doors
Cancel ready mode
when trunk open.
—
—
34
Trunk output
Pulse 0.5 seconds
Pulse 2.5 seconds
Unlock before trunk pulse
0.5sec
Trunk Output at ignition
only
—
—
35 Door unlock Special
application
No special application Activate vehicle ignition
at unlock.
Activate vehicle ignition
and accessory at unlock.
—
—
—
36
Activation/
desactivation remote
Valet Mode
—
by remote :
TRUNK --> LOCK +
UNLOCK or by valet
button.
By Valet button only
—
—
—
37
Security Remote car
starter
Special application
No special application
Security ON: Shutdown
Engine if the door
is opened before
UNLOCK is pressed.
(Door trigger required).
—
—
—
—
38
System control by
OEM Remote
Disable
Enable (Press 3x Lock
to remote start) (Bypass
module required)
—
Enable
Alarm controled by OEM
Remote.
Enable (Press Lock,
Unlock Lock to remote
start) (Bypass module
required)
—
39 AUX1 CONTROLED
BY Temperature
Disable
Enable : AUX1 activated
at +5
o
c when remote
started (see function
25)
—
—
—
—
LEGEND: FUNCTION BY DEFAULT