![Fortec Star DISTEC Brilan 4K Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/fortec-star/distec-brilan-4k-series/distec-brilan-4k-series_user-manual_2321402023.webp)
Brilan 4K monitor controller
23
CMD
Data1
Data2
Data3
Data4
Data5
Description
Range (HEX)
Command
Target
ID
CMD
PARAM
Value
0xF5
(Start Set)
0xF4
(Start Get)
0x88 (Set)
0x89 (Get)
0xXX
(0x00~0xFE)
0xFE/
0xFC Set/
Get Param.
0x6B
0x00~0xFF
(by min-max)
NOT
SEND
IN GET
MODE
POWER
SAFE MODE
TBD
TBD
0x68
RESET
1
0xFE
POWER
0
OFF
1
ON
Notice
(1) CURSOURCE Setting Value
AV1:1, AV2:2, SVIDEO:4, COMP1:7, HDIM:11, DVI12, DSUB:10, MMP:15
(2) MAX_ILLUMINANCE Settings
Setting Value = Ambient Level (by LUX) / 100
Ex) Desired Ambient is 10000 Lux, Setting is 100 (= 10000 / 100)
(3) MIN_ILLUMINACE Settings
Setting Value = Ambient Level (by LUX) / 10
Ex) Desired Ambient is 200 Lux, Setting is 20 (= 200 / 10)
(4) DIM_LEVEL Settings
Dimming is controlled by Brightness Settings.
(5) TEMPERATURE Settings
Setting Value = Desired temperture(by Celsius) x 2 + 60
Ex) Desired temperature is 60°C, Setting is 180 (= 60 x 2 + 60)
(6) TEMP_HYSTERESIS Settings
Setting Value = Desired Hysteresis(by Celsius) x 2
Ex) Desired Hysteresis is 2°C, Setting is 4 (= 2 x 2)
(7) ILLUMINACE
Current lux/10. If Cur_lux>2550 then Value=255
(8) Read only Command
(9) Gap Settings
Setting Value =(int) (1000 * Gap / Active)