Table 1. Welder Specifications
Primary (input) volts
120 V
Maximum Output
125 A
Welding Range
65-80 Amps
Phase
Single
Frequency
60Hz
CSA Rated Output Amps
60
Duty Cycle Rating
20%
Select a clean, dry location with adequate working space around all components. Provide at least two
feet of space in front of and behind the unit to allow for free flow of air.
WARNING:
High voltage danger from power source! Consult a qualified electrician for proper
installation of receptacle at the power source.
This welder must be grounded while in use to protect the operator from electrical shock. If you are not
sure if your outlet is properly grounded, have it checked by a qualified electrician.Do not cut off the
grounding prong or alter the plug in any way and do not use any adapters between the welder’s power
cord and the power source receptacle.
Make sure the POWER switch is OFF then connect your welder’s power cord to a properly grounded
120 Volt AC, 60 Hz, single phase, 20 amp power source. Do not operate this welder if the source
voltage is less than 105 Volts or greater than 132 Volts. Contact a qualified electrician if this problem
exists. Improper performance and/or damage to the welder will result if operated on inadequate or
excessive power.
For optimum welder performance, an extension cord should not be used unless absolutely necessary.
If necessary, care must be taken in selecting an extension cord appropriate for use with your specific
welder.
Select a properly grounded extension cord that will mate directly with the AC power source receptacle
and the welder power cord without the use of adapters. Make certain that the extension cord is properly
wired and in good electrical condition. Extension cords must fit the following wire size guidelines:
• 25 ft. requires #12 gauge
• Do not use an extension cord over 25 ft. in length.
Installation
Welder Specifications
Site Selection
Power Source Connection
Extension Cords
Содержание 125 FC
Страница 25: ...25 WWW FORNEYIND COM Wiring Diagram...