Safety

For complete information, see the included Safety Guide and 

formlabs.com/ipa

.

 Wash parts in a well-ventilated area, away from 

possible sources of ignition. Refer to the isopropyl alcohol (IPA) 
supplier for instructions on safe handling and disposal, and always 
wear gloves when handling IPA. 

Basic Care

REAR TOOL STORAGE

 

Clean the hand-held tools with fresh IPA, then store them in the  

rear storage on Form Wash’s right and left sides.

MAINTENANCE

 

Use the hydrometer to periodically check the resin concentration of  
the IPA. For best surface finish, use fresh IPA to wash printed parts.

PRESERVE QUALITY

 

Use separate wash baskets and wash buckets to preserve part color 
and quality. Use separate equipment for biocompatible materials. 

Additional Supplies

Isopropyl alcohol (IPA), 90% or higher

Powder-free disposable gloves

Paper towels

More Information

Video tutorials and more instructions: 

support.formlabs.com

Washing recommendations:

 

formlabs.com/wash-support

Keep this manual for future reference.

ADDITIONAL RESOURCES

VISIT FORMLABS.COM FOR

This guide is available in other languages on support.formlabs.com.

Help Articles

Discussion Forums

Email Support

Chat Support

Содержание Form Wash

Страница 1: ...Form Wash Print Wash Cure...

Страница 2: ...owing parts to be lowered or raised from the bucket 6 Wash Bucket The removable container holds a maximum of 8 6 L of IPA A rotating impeller at the bottom circulates IPA 7 Display Shows status time a...

Страница 3: ...A s resin concentration based on previous calibration in fresh IPA See page 5 D Scraper Can be used to remove parts from the build platform as well as to carefully clean and inspect the resin tank for...

Страница 4: ...A to reach a level between the minimum 7 8 L and maximum 8 6 L fill lines For more information about using a siphon see Changing the IPA on page 9 NOTE For more information on buying handling safe sto...

Страница 5: ...also be calibrated in a smaller container of fresh IPA To calibrate the hydrometer hold the handle and release the tool in the wash bucket s fresh IPA Slide the O ring along the ribbed stem until the...

Страница 6: ...the basket either as an alternative or in addition to the platform mount Place parts directly in the basket after removing them from the build platform using the removal tool scraper or flush cutters...

Страница 7: ...g After washing parts on the build platform use the removal tool scraper or flush cutters to remove parts Learn more about part removal and preparing prints for use in Form Cure at formlabs com cure s...

Страница 8: ...concentration increases the weight will float higher and the stem and O ring will rise For a smooth dry surface finish replace IPA when the O ring rises above the float s tall wings Checking IPA Resi...

Страница 9: ...IPA 1 REMOVE THE WASH BUCKET AND INNER LID Start with the outer lid open the platform mount raised and the basket removed Lift the wash bucket forward and upward to remove it from the base Set the wa...

Страница 10: ...check the resin concentration of the IPA For best surface finish use fresh IPA to wash printed parts PRESERVE QUALITY Use separate wash baskets and wash buckets to preserve part color and quality Use...

Страница 11: ...A Complete System For Cleaner Stronger Parts Form Wash Form Cure...

Страница 12: ...REV 02 12 2017...

Отзывы: