To prepare the machine:
1. Always remove the turntable and any printed parts before moving or packaging the machine.
2. Wipe residual liquid resin and solvent from the post-curing chamber and other internal
components.
Do not ship the machine with any liquid resin or solvent inside. Liquids left inside the
machine can leak during transit, which may result in additional fees, void the warranty,
or present a safety hazard.
Do not ship the Form Cure L with any loose items stored inside the machine. Loose items can
shift during transit and damage sensitive components, which may result in additional fees or
void the warranty.
When shipping a machine to Formlabs or a certified service provider for
replacement or repair, the power cable and other accessories should not be
shipped and will not be returned after service. Original packaging is required for
warranty service. Contact Formlabs Support or a certified service provider for
unique guidance on shipping requirements.
4.8.2
Packaging
Thoroughly read and follow the instructions to properly package the machine. Skipping
any of the following steps may result in shipping damage and void the warranty.
To package the machine:
1. If you have previously collapsed the machine’s outer cardboard carton, start by reassembling
and securely taping the box.
2. Tilt one side of the machine up and slide a carrying sling underneath. Repeat with a second
sling under the other side of the machine.
3. Place the foam carrier tray insert into the cardboard carrier tray.
4. Use the provided handles on the carrying slings to lift the machine into its carrier tray.
Lifting hazard: The Form Cure L is a heavy object. A two-person lift is required to
prevent injury and avoid damage to the machine.
5. Place the two foam inserts on the top edges of the machine.
6. Lower the outer box onto the machine.
7. Seal each edge of the opening with adhesive packing tape.