Safety
It is vital that any person using this machine and the person(s) responsible for the health & safety is
made fully aware of the potential hazards that could arise from the use and misuse.
These can be broadly categorised as: -
1. Electric Shock.
This machine uses Voltages up to 230V.
NEVER ATTEMPT ANY REPAIR UNLESS THE ELECTRICAL SUPPLY HAS BEEN LOCKED IN THE OFF POSITION.
ONLY SWITCH ON WHEN ALL COVERS & GUARDS HAVE BEEN REPLACED.
ONLY A QUALIFIED ELECTRICAL TECHNICIAN MAY WORK ON ANY PARTS CARRYING MAINS VOLTAGE
AND SHOULD BE RESPONSIBLE FOR ENSURING THAT THE MACHINE IS IN A SAFE CONDITION BEFORE
ALLOWING SERVICES TO BE RESTORED.
2. Burning.
Parts of this machine reach temperatures in excess of 500°C over large areas.
WAIT UNTIL THE MACHINE HAS COOLED DOWN BEFORE SERVICE WORK COMMENCES.
SPECIAL PRECAUTIONS MUST BE TAKEN TO ENSURE THAT ONLY THE MACHINE OPERATOR IS IN THE
OPERATING AREA DURING USE.
USE PERSONAL PROTECTIVE EQUIPMENT SUCH AS GLOVES WHEN TESTING THE HEATED PLASTIC,
HANDLING HOT VACUUM FORMED PARTS, MANUALLY ASSISTING THE FORMING PROCESSS AND
TOUCHING HOT SURFACES.
INFRARED RADIATION IS EMITTED BY THE QUARTZ HEATERS, ENSURE THAT ANY EXPOSURE TO THIS TYPE
OF RADIATION IS SHORT OR COMPLETELY AVOIDED.
3. Injury from Compressed Air.
Pressures up to 100 PSI will be present in large volumes on this machine.
BE EXTRA CAUTIOUS WHEN DEALING WITH COMPRESSED AIR EVEN AFTER THE MAIN SUPPLY HAS BEEN
SHUT OFF DANGEROUS RESIDUAL PRESSURE MAY STILL BE PRESENT WITHIN THE SYSTEM.
4. Toxic Fume Inhalation.
When large sheets of plastic are heated fumes will be given off.
ENSURE THAT THE MACHINE IS POSITIONED IN AN ADEQUATELY VENTILATED PLACE. ASSESS THE RISKS
OF THE MATERIALS TO BE FORMED PRIOR TO USE.
5. Injury from Moving Parts.
Where pneumatics components are used to power moving parts there is a risk of personal injury.
NEVER REMOVE ANY PANEL OR ATTEMPT ANY REPAIR UNLESS THE COMPRESSED AIR SUPPLY AND THE
ELECTRIC SUPPLY HAS BEEN DISCONNECTED.
BE EXTRA CAUTIOUS WHEN DEALING WITH COMPRESSED AIR. EVEN AFTER MAIN SUPPLY HAS BEEN SHUT
OFF DANGEROUS RESIDUAL PRESSURE MAY STILL BE PRESENT WITHIN THE SYSTEM.
NEVER ATTEMPT TO OVERIDE ANY CONTROL SYSTEM INTERLOCK OR SAFETY RELATED CONTROL SYSTEM
SUCH AS THE 2 HANDED CONTROL SYSTEM.
HEALTH & SAFETY - Hazards specific to this machine.
Содержание IMD508
Страница 36: ...Manual Formech IMD508 36 Electrical Schematic 1 2 ...
Страница 37: ...Manual Formech IMD508 37 Electrical Schematic 3 4 ...
Страница 38: ...Manual Formech IMD508 38 Electrical Schematic 5 6 ...
Страница 39: ...Manual Formech IMD508 39 Electrical Schematic 7 8 ...
Страница 40: ...Manual Formech IMD508 40 Electrical Schematic 9 10 ...
Страница 41: ...Manual Formech IMD508 41 Electrical Schematic 11 12 ...
Страница 42: ...Manual Formech IMD508 42 Electrical Schematic 13 14 ...
Страница 43: ...Manual Formech IMD508 43 Electrical Schematic 15 16 ...
Страница 44: ...Manual Formech IMD508 44 Electrical Schematic 17 18 ...
Страница 45: ...Manual Formech IMD508 45 Electrical Schematic 19 20 ...
Страница 46: ...Manual Formech IMD508 46 Electrical Schematic 21 22 ...
Страница 47: ...Manual Formech IMD508 47 Electrical Schematic 23 24 ...
Страница 48: ...Manual Formech IMD508 48 Electrical Schematic 25 26 ...
Страница 49: ...Manual Formech IMD508 49 Electrical Schematic 27 28 ...
Страница 50: ...Manual Formech IMD508 50 Electrical Schematic 29 30 ...
Страница 51: ...Manual Formech IMD508 51 Electrical Schematic 31 32 ...
Страница 52: ...Manual Formech IMD508 52 Electrical Schematic 33 34 ...