Periodic Maintenance
Ongoing routine ‘In Process’ checks & work area housekeeping may be performed during normal operation.
Monitoring and reporting of machine performance may allow maintenance requirements to be dealt with
before wear, damage or when process problems occur. The following schedule indicates such checks /
activities.
Inspection / Check
Daily
Weekly
Monthly Annually
Air Pressure set at 6 Bar
X
Monitor for air leaks
X
Check integrity of all mould table and clamp frame seals
X
Test Emergency stop operation
X
Perform Safety Light Curtain check before 1st operation
X
Visible condition of clamp, table & heater sensors / switches
X
General safety & housekeeping of overall working
environment around equipment
X
Clamp frame adjustment depending upon material
As required
Monitor Pyrometer consistence (Option)
As required
Check Clamping and Table silicone seals
X
Clean Bottom heater glass (if fitted)
X
Inspect heating elements for damage and hairline cracks
X
X
Replace / clean vacuum pump filtering
X
X
Drain vacuum tank
X
Lubricate major mechanical assemblies
X
X
Inspect Pneumatics system
X
Clean Auto-level & bottom heater safety sensor optics
X
Check Security of Fan units
X
X
X
Full Formech major service routine – dependant on utilisation
X
Areas to be monitored
Effectiveness of process functionality
Observation of sensor functionality
Observation of heating element functionality
Fault / event logging
Job data housekeeping
General work method housekeeping and safety of self and others
Monitoring for Hazardous & Dangerous situations
The following Periodic Maintenance Schedule summarises the regular maintenance required by the IMD508.
Owners, designated responsible people and persons required to perform any level of maintenance / servicing
must read the Formech IMD508 manual thoroughly. Particular attention must be paid to references and
notices regarding safety.
The maintenance requirements will very depending on the level of machine utilisation.
Содержание IMD508
Страница 36: ...Manual Formech IMD508 36 Electrical Schematic 1 2 ...
Страница 37: ...Manual Formech IMD508 37 Electrical Schematic 3 4 ...
Страница 38: ...Manual Formech IMD508 38 Electrical Schematic 5 6 ...
Страница 39: ...Manual Formech IMD508 39 Electrical Schematic 7 8 ...
Страница 40: ...Manual Formech IMD508 40 Electrical Schematic 9 10 ...
Страница 41: ...Manual Formech IMD508 41 Electrical Schematic 11 12 ...
Страница 42: ...Manual Formech IMD508 42 Electrical Schematic 13 14 ...
Страница 43: ...Manual Formech IMD508 43 Electrical Schematic 15 16 ...
Страница 44: ...Manual Formech IMD508 44 Electrical Schematic 17 18 ...
Страница 45: ...Manual Formech IMD508 45 Electrical Schematic 19 20 ...
Страница 46: ...Manual Formech IMD508 46 Electrical Schematic 21 22 ...
Страница 47: ...Manual Formech IMD508 47 Electrical Schematic 23 24 ...
Страница 48: ...Manual Formech IMD508 48 Electrical Schematic 25 26 ...
Страница 49: ...Manual Formech IMD508 49 Electrical Schematic 27 28 ...
Страница 50: ...Manual Formech IMD508 50 Electrical Schematic 29 30 ...
Страница 51: ...Manual Formech IMD508 51 Electrical Schematic 31 32 ...
Страница 52: ...Manual Formech IMD508 52 Electrical Schematic 33 34 ...