Service counters
This menu allows you to read, set, or reset the service counters: • The "since last visit" counter can be reset to zero.
• The "since installation" counter can be displayed.
• The "next visit after" counter can be:
- incremented in 5000 steps to a maximum value of 6.000.000 steps.
- decremented in 5000 steps to a minimum of 5000 steps. A value under 5000 results in the value OFF.
• The "feeder" counters (1 through 3) can be reset to zero.
• The "envelope hopper" counter can be reset to zero.
Reading: OMR
OMR code definition
The OMR code definition menu allows you to define the OMR reading codes.
The Table summarizes the possibilities of the OMR code.
• When some functions are not used, marks will shift up.
• The minimum amount of marks are: Start mark + accumulate or insert. That is 2
marks in total. However, it is highly recommended to add a third mark, the safety
mark in the minimum configuration.
• The feeders programmed as selective feeder cannot be used as a reading feeder.
• The sequence will be reset after power up; a job change; a successful clear action
or an error message.
• When parity is used the parity of the printed marks should be even.