Section 5 - Water Distribution System
Foretravel Owners Manual
Page 5-3
Rev. 06-02
COLD WEATHER OPERATION
It is important to understand the interior water lines, fixtures, supply tank,
pump and filter are normally protected from moderate freezing temperatures,
as long as the furnace remains in operation.
However, please keep in mind
that your motorhome was not designed for prolonged use in sub-freezing
temperatures without implementing special precautions.
PHYSICAL PROTECTION OF INTERIOR WATER LINES
Be careful not to store heavy items such as canned goods, tools, etc., in ar-
eas where they may come in contact with water piping and cause damage due
to road vibration and shifting of the load.
PRECAUTIONS FOR USING WASHER/DRYER UNITS
Use caution when using your washer/dryer. Make certain that you have
adequate holding tank capacity or are hooked to a drain line with the drain
valve open. Failure to do so could result in a flooded coach due to the large
amount of water used in the washer/dryer. See washer/dryer manual for details.
W
INTERIZING
Y
OUR
M
OTORHOME
1. Turn off LP gas (and electric power to 3 way water heater and hot water
dispenser if so equipped). Failure to do so could result in damage to these
items.
2. Open and leave open all faucets in the coach.
3. Open pop-off valve on water heater tank or Aqua-Hot tank
(to avoid pos-
sible danger of scalding, be sure water heater is OFF and water is not
hot)
, and remove drain plug.
4. Open kitchen faucet to center position. If equipped with a hot water dis-
penser, it must be unplugged and drained. See manufacturers instructions.
5. Open all (usually 3) drain valves. For locations see "Water Drains".
6. Open and drain holding tanks.
7. Turn water pump on for 5 seconds (after all systems are drained) to remove
water from internal workings of pump.
8. Flush and hold open water step valve on toilet for 10 seconds to remove wa-
ter from internal portion of toilet.
9. Remove water purifier cartridge if so equipped.
10. Check antifreeze in coach engine cooling system, and bring to protection
required.
11. Open drain valve at bottom of the utility compartment faucet.
Содержание GV320
Страница 2: ......
Страница 4: ......
Страница 52: ...Section 7 LP Gas Systems Page 7 10 Foretravel Owners Manual Rev 09 02 This Page Intentionally Blank ...
Страница 64: ...Section 9 Heating and Cooling Page 9 4 Foretravel Owners Manual Rev 06 02 This Page Intentionally Blank ...
Страница 98: ...Section 16 Towing Page 16 4 Foretravel Owners Manual Rev 06 02 This Page Intentionally Blank ...
Страница 102: ...Section 18 Electrical Test Information Page 18 2 Foretravel Owners Manual Rev 06 02 TRAILER LIGHTS HOOK UP DIAGRAM ...
Страница 108: ...Appendix B ATEC Transmission Codes Page B 2 Foretravel Owners Manual Rev 06 02 This Page Intentionally Blank ...
Страница 112: ...Appendix D Tires Page D 2 Foretravel Owners Manual Rev 06 02 This Page Intentionally Blank ...
Страница 114: ...Appendix E Air System Page E 2 Foretravel Owners Manual Rev 06 02 This Page Intentionally Blank ...