Installing the Forest Shuttle

®

 S / M / L  

Z-Wave

 

 

Advanced Z-Wave configuration of the 

FOREST SHUTTLE®  S / M / L  

Z-Wave

 

 
Z-Wave Plus: Yes 
Z+ Plus Role type: ROLE_TYPE_SLAVE_ALWAYS_ON 
Z+ Device type: WINDOW_COVERING_POSITION_ENDPOINT_AWARE 
Basic type: BASIC_TYPE_ROUTING_SLAVE 
Generic type: GENERIC_TYPE_SWITCH_MULTILEVEL 
Specific type: SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL 
Listening: TRUE 
Z-Wave Lib: 6.51.10 

 

Supporting command classes 

 

class: 0x5E COMMAND_CLASS_ZWAVEPLUS_INFO_V2 
class: 0x85 COMMAND_CLASS_ASSOCIATION_V2 
class: 0x59 COMMAND_CLASS_ASSOCIATION_GRP_INFO 
class: 0x25 COMMAND_CLASS_SWITCH_BINARY 
class: 0x26 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 
class: 0x86 COMMAND_CLASS_VERSION_V2 
class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 
class: 0x5A COMMAND_CLASS_DEVICE_RESET_LOCALLY 
class: 0x27 COMMAND_CLASS_SWITCH_ALL 
class: 0x73 COMMAND_CLASS_POWERLEVEL 
class: 0x7A COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 

 

Routing slave 

This Z-Wave product will be used as slave. Slave nodes are nodes in a Z-Wave network that receive commands and perform 
actions based on the command. A routing slave can route Z-Wave messages to other nodes in the network.  

 

Always on slave 

The Z-Wave 

plus role type of this routing slave product is ‘slave always on’. 

 

That means that this device is always awake and does not go to sleep mode because it is an AC powered device. It is always 
available for communication with a controller.   
 
This device can also act as a wireless repeater to forward commands for another device in the Z - Wave network to expand the 
range of the network. This function works for every Z - Wave device from any manufacturer when included into the same Z - 
Wave network. Unlike a normal slave a routing slave can store a number of static routes which he uses to send a routed RF 
frame to another node.  

 

Include initiator  

The include initiator is used when Primary and Inclusion Controllers include nodes into the network. When both the include 
initiator have been activated simultaneously the new node will be included to the network ( 
if the node was not included previously) 

 

Exclude initiator  

The exclude initiator is used by Primary Controllers to exclude nodes from the network. When the exclude initiator and a slave 
initiator are activated simultaneously, it will result in the slave being excluded from the  
network (and reset to Node ID zero). Even if the slave was not part of the network it will still be reset by this action.  
 

Z-Wave compatibility 

Because this is a Z-Wave device, it means it can co-operate with other Z-Wave devices of other manufacturers. It can co-exist in 
a Z-Wave network existing with product from other manufacturers. 
 

Hops & retries 

The Z-Wave range has a range of up to 40 meters in line of sight. This signal is not limited to the 40 meters range due to routing 
the Z-Wave message to other nodes in the network. This way the range of the Z-Wave network can be expanded to 160 meters 
indoors (limit of 4 hops).  
 

Содержание SHUTTLE L Z-Wave

Страница 1: ...Installing the FOREST SHUTTLE S M L Z Wave ...

Страница 2: ... after the end positions have been set position the master carrier s into half open position Attach the motor to the track make sure to secure the locking pin into the motor pulley Shuttle L Z Wave Shuttle S M Z Wave USA Connect the AC plug 100 240V Connect the 24V plug into the socket of to the power socket of Shuttle L the Shuttle S and connect the AC plug to the wall socket loop the cord throug...

Страница 3: ...ravel automatically towards the closed position SETTING OPEN LIMIT When the closed position is reached that end limit is set Pull the master carrier s to the open position The master carrier s will travel automatically towards the open position Stack back When the master carrier reaches the fully open position it will stop yellow LED4 is on Now the open limit setting can be adjusted by hand by rem...

Страница 4: ...ced Z Wave learning out Product Reset Please use this procedure only when your network primary controller is missing or otherwise inoperable Press the configuration button 25 times and confirm by pressing the button once more for 4 seconds until the led blinks 3 times and goes OFF This way of excluding is less preferred Please use this procedure only when the network primary controller is missing ...

Страница 5: ... 13x 14x or 15x button and confirm by pressing button once more for 4 seconds until the led blinks 3 times and goes OFF The IR receiver can only be connected to port 1 Place the eye of the receiver cord in view of the IR remote If necessary change the IR channel as shown on page 4 Factory default To reset all settings press button 16x To confirm press button once more for 4 seconds until the led b...

Страница 6: ...is connected to pin 3 COMMON the Shuttle will open the curtain CLOSE when pin 8 is connected to pin 3 COMMON the Shuttle will close the curtain STOP when pin 1 and 8 are connected to pin 3 COMMON the Shuttle will stop moving the curtain Different modes can be set Pulse when short contact is made the curtain will open or close fully default setting Continuous the curtain will move as long as the co...

Страница 7: ...r communication with a controller This device can also act as a wireless repeater to forward commands for another device in the Z Wave network to expand the range of the network This function works for every Z Wave device from any manufacturer when included into the same Z Wave network Unlike a normal slave a routing slave can store a number of static routes which he uses to send a routed RF frame...

Страница 8: ... is fully open 0x00 is fully closed 0x01 0x63 is a curtain rail position COMMAND_CLASS_ASSOCIATION_V2 The Association Command Class is used to associate other devices with the Shuttle LZ The Shuttle LZ only has 1 supported association group This group holds the lifeline to the controller according to Z Wave Plus standards Group 1 lifeline Maximum supported nodes per group 1 The node associated in ...

Страница 9: ...multilevel start level command is received The curtain reached an end position fully open or full closed Supported Report Because of version 3 of this command class the Shuttle LZ responds with the following types Primary Switch Type 0x03 o 0xFF is Open o 0x00 is Closed Secondary Switch Type 0x00 NOT SUPPORTED NOTE 1 due to the limitations of this type of multilevel a curtain rail the Duration byt...

Страница 10: ...ually the DEVICE_RESET_LOCALLY_NOTIFICATION command is sent to node associated in the lifeline association group COMMAND_CLASS_SWITCH_ALL The Shuttle LZ supports switch all functionality and therefore can be in included in a switch all broadcast If Shuttle LZ is configured to switch all mode 0x00 is excluded from all switch on off functionality 0x01 is excluded from the all on but not the all off ...

Страница 11: ... IP20 IP20 IP20 Max running time in one direction 240 sec 240 sec 240 sec Sound level 40dB 40dB 40dB Ambient temperature 0 40 C 32 104 F 0 40 C 32 104 F 0 40 C 32 104 F Relative humidity 10 80 10 80 10 80 Maximum useable altitude above sea level 2000m 6561ft 2000m 6561ft 2000m 6561ft Certification Marking CE CE CE TECHNICAL SPECIFICATION POWER SUPPLY Shuttle S Shuttle M Receiver Model ZDA240150 ZF...

Страница 12: ... all components of the curtain track and power supply adaptor Forest Group does not assume liability for resulting damages to property or personal injury defects labour on location service calls reinstallation or expenses involved shipping packing or returning goods if the product has been abused modified in any way or damaged by improper use or failure to observe these operating instructions The ...

Отзывы: