Ford Connected Wall Box
Ford Connected Wall Box Operation manual
7
SKLJ98-10C823-BA
NOTE
In addition to the safety instructions in this doc-
ument, also observe further safety instructions
in any other enclosed documents.
3
Unit description
These operating and installation instructions describe the
Ford Connected Wall Box. You can find the exact device de-
tails on the type label of the Ford Connected Wall Box.
Electrical Character-
istics
IEC
Rated voltage (V AC) 230 / 400 V
Rated current (A AC) 16A, 3-phase
32A, 1-phase
Grid frequency (Hz)
50
Network types
TN / TT (1P+N+PE
or 3P+N+PE):
P to N = 230 V AC; P to P = 400 V
AC
IT (1P+N+PE):
P to N = 230 V AC
Output voltage (V AC) 230 / 400 V
Maximum charging
power (kW)
11 kW (TN and TT network, 3-phase,
depending on country-specific lim-
itations)
7.4 (TN, TT and IT network, 1-phase,
depending on country-specific lim-
itations)
You can also use a 3-phase wall box
to
charge a 1-phase connection.
Check national requirements for
connection to a TN network.
The Ford Connected Wall Box does
not comply with BS7671 for connec-
tion to TN networks in the United
Kingdom.
Electrical Character-
istics
IEC
EMC class
Emitted interference: Class B
(residential, business, commercial
areas)
Immunity: industrial areas
Overvoltage category II, as per EN 60664
Protection class
I
Protective devices
A residual current circuit breaker
must be provided from the installa-
tion side. See Criteria for the elec-
trical connection.
Integrated power
meter
Ac/- 5 %
Connections
Cable feed
Mounted on-wall, or in-wall
Connection cross-sec-
tion
(wire dimension)
Cross-section of the connection
cable must comply with local
codes/regulations. Connection at
Power Input inside.
Charging cable includ-
ing coupler
Type 2 charging cable according to
EN 62196-1 and EN 62196-2
Cable length 7.5 m
Max. charging capacity
(kW)
7.4 kW (1 phase) Maximum capacity
adjustable via DIP switches
11 kW (3 phase) Maximum capacity
adjustable via DIP switches
Communication & fea-
tures
Vehicle–charger Com-
munication Protocol
(CP)
IEC 61851-1:2017, Annex A
Display
9 RGB LEDs
Network interfaces
Wi-Fi / WLAN 802.11n - 150 Mbit/s
Authentication and
Mobile communica-
tions
Bluetooth (BLE 4.2) – Setup app
OCPP
Version 1.6
Mechanical data
Electrical Character-
istics
IEC
Dimensions (W × H ×
D)
258 x 450 x 141 mm
10.2 x 17.7 x 5.5 inches
Weight (including
Wall Mount Bracket &
Charging Cable)
6,02 kg
13.27 lbs
Installation height
Minimally 900 mm / 35.5 inches
above floor level
measured to / from the bottom of
the device
IP protection class,
device
IP65
Protection against
mechanical impact
IK10
Ambient conditions
Operating temperat-
ure range
-30 °C to +50 °C
-22 °F to +122 °F
Storage temperature
range (°C)
-40 °C to +85 °C
-40 °F to +210 °F
Altitude (m)
Max. 3,000 m above sea level
Max. 9,842 ft above sea level
Certification compat-
ibility
Other standards and
guidelines
l
2014/53/EU (Radio Equipment
Directive) [OJ L 153, 22.5.2014, p.
62-106]
l
2011/65/EU (RoHS-Directive)
[OJ L 174, 1.7.2011, p. 88-110]
l
2014/53/EU – Art.3 (1) a) Sich-
erheit
l
EN IEC 61851-1:2019; EN
61439-1:2011; IEC 61439-7:2018,
IEC 62955:2018 (RDC-MD),
l
EN 62233:2008
l
2014/53/EU – Art.3 (1) a) Sich-
erheit (Funkteil)
l
EN 62368-1:2014; EN 62311:2008
l
2014/53/EU – Art.3 (1) b) EMV
Содержание Connected Wall Box
Страница 2: ......