SSPARC/CPU-5CE
Installation Guide
CAUTION: To avoid damaging the serial ports, please consider the following regarding
Switch 3 and Switch 4. Do not set the switches (SW3-1 and SW3-2), or (SW3-3 and SW3-4),
or (SW3-5 and SW3-6) to ON at the same time and do not set the switches (SW4-1 and
SW4-2), or (SW4-3 and SW4-4), or (SW4-5 and SW4-6) to ON at the same time!
SWITCH 9
SW9-2
SW9-1
ON
ON
External VMEbus SYSRESET
ON = VMEbus SYSRESET generates on-board
RESET
OFF = VMEbus SYSRESET does not
generate on-board RESET
VMEbus SYSRESET generation
ON = SYSRESET is driven to VMEbus, if board
is Slot-1 Device
OFF = SYSRESET is not driven to VMEbus
Table 1: Default Switch Settings (cont.)
Diagram of Switch
Switches
Default
Setting
Function
1
2
SW9
ON
OFF