15
Sanitising
Instructions
1) Make a mild cleaning solution of chlorine bleach
and potable water in the plastic bowl.
2) Turn off RO system, drain storage tank and
remove membrane element and pre-filter and
post-filter.
3) Membrane element must remain wet. Put
membrane element in a plastic bag.
4) Fill empty pre-filter housing with sanitising solution
and turn on raw water. After the tank is full, let the
system stand idle for approximately 10 minutes
5) Turn off water.
6) Drain storage tank via the RO Faucet.
7) Re-install new pre-filters and membrane element.
8) Replace post-filter.
9) Disconnect lines to faucet and put approximately
10 drops of sanitising solution in these lines and
reconnect.
10) Flush carbon fines and bleach from lines after the
system has started purifying water again.