![FOR-A USF-105DADA Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/for-a/usf-105dada/usf-105dada_operation-manual_2316629017.webp)
17
9. Extended Distribution Using Multiple USF-105DADAs
Internal Bus Configuration
Applying multiple USF-105DADAs enable you to increase the distribution number via a USF frame
internal bus.
Up to 4 USF-105DADAs can be applied and 20 distributed, from 1 input. Install USF-105DADAs in the
internal bus slot that is the same as for the input signal. (Slot 1 to 4, Slot 5 to 8, or Slot 9 to 12)
Set DS2, and Switch 3 to 7 to increase distribution number via an internal bus. See Sec. 3-4
“DS2
Switches 3 and 4: Input Signal Switches Settings
” and Sec. 3-5 “DS2 Switch 5, 6, and 7: Internal Bus
Switch Output Settings
” for details on switch settings.
IMPORTANT
When using USF-105DADA units in a USF frame internal bus, apply multiple USF-105DADAs to
extend distributions. Other USF modules cannot be combined with USF-105DADA for this purpose.
When using an internal bus, ensure that the settings do not affect other modules.
Slot
9 - 12
Slot
5 - 8
Slot
1 - 4