7. Web GUI Setup
Web GUI can be displayed when a USF-105DADA is installed into a USF-212S frame, but is not
displayed when it is installed into a USF-212 frame. See USF-212S operation manual for details on
displaying a Web GUI.
Launch Web GUI and click USF-105DADA from slot no.1 to 12 of the USF-212S. The screen below
opens.
Module Information
Item
Description
Slot
Installed slot number of USF-212S
S/N
USF-105DADA serial number
MAC Address
USF-105DADA MAC address
Software Version
USF-105DADA software version
FPGA Version
USF-105DADA FPGA version
IP Address
USF-105DADA IP address
Installed Cards
Installed cards matching
Matched: Matched cards are installed.
Mismatched: A mismatched rear card is installed. Install a correct rear card.
CPU Temperature CPU temperature on the USF-105DADA
Input
Input signal condition
Detected: Signal is correctly input.
Not Detected: Input signal is not detected.
See Sec.5
“Input Signal Detection” for details.
* When an input signal is set to be input other than via a rear BNC connector, the
input signal is not detected and
“------“ is indicated.
Input Status Trap
When monitoring using SNMP Manager,
Enable: Sends input status trap
Disable: Not send input status trap
* When an input signal is set to be input other than via a rear BNC connector, the
input signal is not detected and a trap is not sent out.
See Sec. 5
“Input Signal Detection” for trap sending conditions. See
Sec. 8
”SNMP (Simple Network Message Protocol) Function” for trap details.
Signal Mode
USF-105DADA signal mode
See Sec. 4
“Signal Mode Setting” for details.