Menu item
Function
Value setting
Default value
Window open
detection
Switched off
Active when temperature set
from 5-25°C
If active, 2nd setting Duration
of the function in minutes
Switched off
Automatic key
lock after 10
minutes
Switched off
Switched on
Switched off
Minimum
adjustable
temperature
1-15°C
5°C
Maximum
adjustable
temperature
16-70°C
35°C
Boost mode
Duration
100-900 seconds
(in steps of 100 seconds)
300 Seconds
Valve position
display
Displays the valve position in
percent
Threshold
valve setting
Threshold value from when the
valve is opened/closed
0.5-1.5°C
1°C
Display
rotation
Normal
180° rotated
Normal
Valve adjust-
ment mode
Intelligent control
Static control according to
temperature
Intelligent
control
Factory settings
Change value from to
and press twice to reset
Valve closure
adjustment
Normal
Strong closing
Normal
GB
GB
29
30
No liability is accepted for any damage caused by incorrect operation.
If you need technical support, please contact our support team at our
website
or check the FAQs in the FontaHome app
or our website at
.
Safety instructions
• Do not dismantle the unit.
• Do not immerse the unit in water and protect it from moisture.
• Never use the appliance if it has visible damage.
• Do not operate the unit outdoors or in rooms with high humidity.
Technical data thermostat
• Batteries: 2xAA
• Valve connection: M30x1.5
• Adjustable temperature: 1°- 70°C
• Frequency band: 2.4GHz (Zigbee)
• Radio range: Up to 30m (unobstructed)
We hereby declare that this appliance bears the CE marking in
accordance with the regulations and specifications. It therefore
complies with the essential requirements of the RED Directive
2014/53/EU and RoHS Directive 2011/65/EU.
You can find the complete declaration of conformity
.