Fondital NIAS BTN 28 Скачать руководство пользователя страница 27

 

27

CH PROBE (SR) AND DHW PROBE (SS) 
TEMPERATURE RELATED RESISTANCE VALUES  

T °C 

0 

1 

2 

3 

4 

5 

6 

7 

8 

0 

33242 51534 29925 28409 26980 25633 24361 23161 22028 20958 

10 

19947 18992 18088 17233 16425 15659 14934 14247 13596 12979 

20 

12394 11839 11313 10813 10338  9888 9459 9052 8665 8297 

30 

7947 7614 7297 6995 6707 6433 6171 5922 5685 5458 

40 

5242 5036 4839 4651 4471 4300 4136 3979 3829 3685 

50 

3548 3417 3291 3171 3056 2945 2840 2738 2641 2548 

60 

2459 2373 2291 2212 2136 2063 1994 1926 1862 1800 

70 

1740 1683 1628 1576 1524 1475 1428 1383 1339 1297 

80 

1256 1217 1180 1143 1109 1075 1042 1011  981  952 

90 

923  896  870  845  820 797 774 752 730 710 

100 

690  671  652  634  617 600 584 568 553 538 

Relation between temperature (°C) and nominal resistance (Ohm) of the CH probe SR and the DHW probe SS 
E.g.:  

25 °C water, nominal resistance is 9888 Oh  
90 °C water, nominal resistance is 923 Ohm 

 

3.6 Switching to different gases 
 
NIAS  boilers are factory-set according to gas 
type requested. 
 
Any later conversion must be performed by 
qualified technicians. FONDITAL  conversion kit 
(supplied with boiler) must be installed.  For 
conversion and adjustment instruction see below. 
 
Converting boiler from one type of gas to 
another:  
- remove the main burner; 
- remove nozzles - “1” in pic. 24 - of main burner 
(13 nozzles on 24 kW models, 15 nozzles on 28 
kW models) (see pic.24) and replace them with 
those corresponding to the new type of gas. 
Check “NOZZLES - PRESSURES” chart for 
nozzle size; 
- install (LPG 24 kW model conversion only) or 
remove (natural gas conversion only) diaphragm 
2 at the outlet of the gas valve (see pic. 25); 
- re-install main burner; 
- position the jumper on the modulation board in 
the electrical panel as shown in pic. 26; 
- check the pressure value upstream the gas 
valve (see “NOZZLES - PRESSURES” chart) and 
adjust the pressure of the burner as indicated in 
the “BURNER ADJUSTMENT” section; 
- check that the burner is functioning properly; 
check that there are no gas leaks. 
 
When the conversion process is completed, fill in 
the label supplied with the kit with the information 
required and stick it onto the boiler alongside the 
rating plate. 

 

NIAS BTN 24 

PRESSURES – NOZZLES CHART 

Burner pressure (mbar) 

Type of gas 

Supply pressure 

(mbar) 

nozzle Ø (mm) 

diaphragm Ø 

(mm) 

Min Max 

Natural gas 

20 

1.20 

2.9 

12.3 

Butane  

28 

0.77 

4.9 

5.3 

23.5 

Propane  

37 

0.77 

4.9 

7.1 

30.3 

 

 

pic. 24

pic. 25

pic. 26 

Содержание NIAS BTN 28

Страница 1: ...NIAS INSTALLATION USE AND MAINTENANCE GB IST 03 C 167 01...

Страница 2: ...Thank you for choosing our boiler Please read these installation and maintenance instructions with care Please note that the boiler must only be installed repaired and serviced by qualified personnel...

Страница 3: ...the packaging as all the materials can be recycled The packaging must therefore be sent to specific waste management sites Keep the packaging out of the reach of children as it may represent a choking...

Страница 4: ...sitioning the boiler page 13 3 2 4 Installing the boiler page 14 3 2 5 Boiler room ventilation page 15 3 2 6 Flue system page 15 3 2 7 Flue system configuration page 17 3 2 8 Flue system with coaxial...

Страница 5: ...the water storage tank from freezing is active Power light B The light indicates that power is being supplied to the boiler Central Heating temperature regulator C The knob sets the heating system wat...

Страница 6: ...re or qualified maintenance personnel If the boiler shuts down frequently this indicates that there is a recurring malfunction In this case contact qualified personnel or an authorised Service Centre...

Страница 7: ...es or until the temperature of the water in the system reaches 15 C WARNING This function is not active if the boiler is disconnected from the power and gas supply and the gas tap is closed The heatin...

Страница 8: ...ruary 1973 amended by Directive 93 68 EEC dated 22 July 1993 NIAS boilers are equipped with safety features according to applicable laws The main technical features of NIAS boilers are below summarize...

Страница 9: ...e 11 Temperature probe 12 Expansion vessel heating system 13 Optional expansion vessel DHW system 14 Water storage tank anode 15 Water storage tank 16 Water storage tank thermostat 17 Overheating shut...

Страница 10: ...HW production by 45 C t 8 9 lts min DHW production by 35 C t 11 5 lts min DHW production by 40 C t 10 lts min DHW production by 30 C t 13 4 lts min 45 C DHW supply during the first 10 minutes storage...

Страница 11: ...4 BTN 28 W 110 Maximum absorbed power BTFS 24 BTFS 28 W 165 Net weight BTN 24 BTN 28 kg 72 5 Net weight BTFS 24 BTFS 28 kg 78 Natural gas consumption BTN 24 BTFS 24 m h min 1 32 max 2 80 Butane consum...

Страница 12: ...1 Flue gas mass g s 16 5 17 7 Flue air temperature C 108 8 CO2 5 9 Boiler efficiency 90 45 88 36 NIAS BTN 28 Heat dispersion from the boiler casing max input min input 30 red load Boiler installed ind...

Страница 13: ...e maintenance operations check wall sturdiness avoid fixing the boiler to thin partitions avoid installing the boiler above appliances which might affect boiler operation E G kitchen appliances emitti...

Страница 14: ...of the above To install the boiler fix the template to the wall by means of four 10 mm screws and dowels IMPORTANT ceiling and screws clearance must be 436 mm position connections of gas supply pipe...

Страница 15: ...conductivity it must be perfectly sealed to prevent cooling due to parasite air inlets it must be as vertical as possible and the end section must have a roof top which ensures efficient and constant...

Страница 16: ...tly check the flue outlet duct This duct may be obstructed or may be unsuitable for the discharge of flue gas into the atmosphere FONDITAL shall not be held responsible for damage resulting in incorre...

Страница 17: ...both end sections must be located within a 500 by 500 mm surface area C42 Boiler connected to collective chimneys including two ducts one for the air intake for combustion and the other for the discha...

Страница 18: ...the outlet point to prevent rain water from getting into the duct Type C32 Minimum length of vertical coaxial ducts is 0 5 meters Maximum allowable length of vertical coaxial ducts is 4 meters includ...

Страница 19: ...BTFS 24 model must be installed as shown in pic 11 diaphragms are supplied with boiler IMPORTANT Should flue system cross walls and or infrastructure or if it easily accessible it is mandatory to inst...

Страница 20: ...facing perimeter walls Maximum allowable load loss 80 Pa Sample No 2 pic 14 Air intake from perimeter wall and flue gas roof outlet Maximum allowable load loss 80 Pa Sample No 3 pic 15 Air intake fro...

Страница 21: ...elbows x 4 8 Pa splitting device 80 12 Pa horizontal 80 air intake terminal 3 Pa horizontal 80 outlet terminal 5 Pa Tot load loss 80 Pa 3 2 10 Measuring combustion efficiency Type A accessories Coaxi...

Страница 22: ...ing always use FONDITAL approved spare part FONDITAL shall not be held liable for damage on injury caused by failure to properly earth the power mains Gas lines DHW and CH pipes are not suitable for e...

Страница 23: ...rge any left air let the system cool down and then adjust water pressure gauge to 0 8 1 bar WARNING For best performance safe trouble free and long lasting operation of boiler and its components in or...

Страница 24: ...r dry any wet surfaces 3 4 Starting the boiler 3 4 1 Preliminary checks Before starting the boiler verify the following correct installation of flue gas outlet duct and the end section when the boiler...

Страница 25: ...brown blue yellow green Power supply 230 V 50 Hz Power supply 230 V 50 Hz CH DHW A1 A6 Utilities connectors AG Anti freeze DK Low water pressure safety switch E I Summer Winter switch IG Main switch...

Страница 26: ...en red teflon E ACC 1 white teflon E RIV pic 23 POWER OUTLETS Modulation board Modulation board black blue orange brown green white red brown blue brown blue black blue orange brown black black black...

Страница 27: ...ed with boiler must be installed For conversion and adjustment instruction see below Converting boiler from one type of gas to another remove the main burner remove nozzles 1 in pic 24 of main burner...

Страница 28: ...regulator pic 27 located on top of the modulation coil set the CH water temperature to maximum connect a U shaped pressure gauge following instructions shown in pic 28 set the heat power regulator P1...

Страница 29: ...nsequently the boiler heat output Burner gas pressure boiler heat output chart pic 30 Assuming the heating system requirement is 18 kW pic 30 chart indicates burner gas pressures to ensure proper boil...

Страница 30: ...owing checks boiler integrity leakage of the boiler s gas circuit and gas mains network boiler gas supply pressure minimum and maximum gas pressures to the boiler nozzles boiler ignition boiler combus...

Страница 31: ...31...

Страница 32: ...to 40 Tel 39 0365 878 31 Fax 39 0365 878 576 e mail info fondital it www fondital it The producer reserves the right to modify the data contained herein at any time without notice Uff Pubblicit Fondit...

Отзывы: