16
pic. 6
Incline
Incline
pic. 7
pic. 8
WARNING:
The boiler is fitted with an automatic safety
reset device as protection against leakage of
combustion products inside the building.
The device includes an automatic bi-metallic
reset thermostat (pic. 8) mounted on the anti
wind gust cover. After 15 minutes the boiler
will automatically restart.
It is absolutely forbidden to tamper with
and/or exclude the safety device.
If the boiler shuts down frequently, check the
flue outlet duct. This duct may be obstructed
or may be unsuitable for the discharge of flue
gas into the atmosphere.
FONDITAL shall not be held responsible
for damage resulting in incorrect
installation, use, modification of the
boilers or for non-observance of the
instructions provided by the manufacturer
or applicable installation standards for
the product.
FORCED DRAUGHT BOILER
The distances of boiler vent terminals on
walls must comply with standards and laws
applicable in the country of installation which
shall be considered as having been
transcribed in full in this manual.
DIMENSIONS FOR CONNECTING THE FLUE SYSTEM DUCTS