Instructions for the installer
51
3.6.4
Ø 100/60 mm and Ø 125/80 mm air/flue gas coaxial duct system
WARNING
The information given above is with reference to air intake/flue gas venting ducts made from smooth, rigid pipes appro
-
ved and supplied by the manufacturer.
C13/C13X installation type
KC 12 - KR 12 - KRB 12
• Minimum permissible length of horizontal coaxial pipes is 1 meter.
•
Maximum permissible length of Ø100/60 mm horizontal coaxial pipes is 9 meters, first curve included.
•
Maximum permissible length of Ø 125/80 mm horizontal coaxial pipes is 30 meters including the first elbow connected to the boiler.
• For each additional 1 meter of straight pipe maximum permissible length is to be reduced by 1 meter.
• For each additional 90° elbow, maximum permissible length is to be reduced by 1 meter.
• For each additional 45° elbow, maximum permissible length is to be reduced by 0.5 meter.
• The wall terminal reduces maximum permissible length by 1.5 meters.
• The air intake duct is to be tilted down by 1% toward its exit, in order to avoid rain water to enter it.
•
The flow resistance of the first elbow shall not be taken into account to calculate maximum permissible length.
KC 24 - KR 24 - KRB 24
• Minimum permissible length of horizontal coaxial pipes is 1 meter.
•
Maximum permissible length of Ø 100/60 mm horizontal coaxial pipes is 10 meters including the first elbow connected to the boiler.
•
Maximum permissible length of Ø 125/80 mm horizontal coaxial pipes is 30 meters including the first elbow connected to the boiler.
• For each additional 1 meter of straight pipe maximum permissible length is to be reduced by 1 meter.
• For each additional 90° elbow, maximum permissible length is to be reduced by 1 meter.
• For each additional 45° elbow, maximum permissible length is to be reduced by 0.5 meter.
• The wall terminal reduces maximum permissible length by 1.5 meters.
• The air intake duct is to be tilted down by 1% toward its exit, in order to avoid rain water to enter it.
•
The flow resistance of the first elbow shall not be taken into account to calculate maximum permissible length.
KC 28 - KR 28 - KRB 28
• Minimum permissible length of horizontal coaxial pipes is 1 meter.
•
Maximum permissible length of Ø100/60 mm horizontal coaxial pipes is 9 meters, first curve included.
•
Maximum permissible length of Ø 125/80 mm horizontal coaxial pipes is 30 meters including the first elbow connected to the boiler.
• For each additional 1 meter of straight pipe maximum permissible length is to be reduced by 1 meter.
• For each additional 90° elbow, maximum permissible length is to be reduced by 1 meter.
• For each additional 45° elbow, maximum permissible length is to be reduced by 0.5 meter.
• The wall terminal reduces maximum permissible length by 1.5 meters.
• The air intake duct is to be tilted down by 1% toward its exit, in order to avoid rain water to enter it.
•
The flow resistance of the first elbow shall not be taken into account to calculate maximum permissible length.
KC 32 - KR 32 - KRB 32
• Minimum permissible length of horizontal coaxial pipes is 1 meter.
•
Maximum permissible length of Ø 100/60 mm horizontal coaxial pipes is 7 meters including the first elbow connected to the boiler.
•
Maximum permissible length of Ø 125/80 mm horizontal coaxial pipes is 30 meters including the first elbow connected to the boiler.
• For each additional 1 meter of straight pipe maximum permissible length is to be reduced by 1 meter.
• For each additional 90° elbow, maximum permissible length is to be reduced by 1 meter.
• For each additional 45° elbow, maximum permissible length is to be reduced by 0.5 meter.
• The wall terminal reduces maximum permissible length by 1.5 meters.
• The air intake duct is to be tilted down by 1% toward its exit, in order to avoid rain water to enter it.
•
The flow resistance of the first elbow shall not be taken into account to calculate maximum permissible length.
Содержание ITACA KC 24
Страница 8: ...8 7 Malfunctions possible causes and solutions 92 7 1 Troubleshooting 92...
Страница 69: ...Instructions for the installer 69 Fig 26 Available head KC KR KRB 24 Fig 27 Available head KC KR KRB 28...
Страница 97: ...97 Page left intentionally blank...
Страница 98: ...98 Page left intentionally blank...
Страница 99: ...99 Page left intentionally blank...