Technical features and dimensions
37
2.5 General characteristics
Description
um
KC 12
KC 24
KC 28
KC 32
CH nominal heat input
kW
12,0
23,7
26,4
30,4
Minimum heat input
kW
2,0
3,0
3,3
4,2
Maximum heat output (80-60°C) - CH
kW
11,7
23,0
25,5
29,4
Minimum heat output (80-60°C) - CH
kW
1,8
2,6
3,0
3,9
Maximum heat output (50-30°C) - CH
kW
12,6
25,0
27,9
32,3
Minimum heat output (50-30°C) - CH
kW
2,1
3,2
3,5
4,4
Minimum CH system pressure
bar
0,5
0,5
0,5
0,5
Maximum CH system pressure
bar
3,0
3,0
3,0
3,0
DHW maximum heat input
kW
18,0
27,3
30,4
34,5
DHW minimum heat input
kW
2,0
3,0
3,3
4,2
DHW circuit min. pressure
bar
0,5
0,5
0,5
0,5
DHW circuit max. pressure
bar
6,0
6,0
6,0
6,0
DHW specific flow rate (ΔT=25K)
l/min
10,6
16,1
18,6
19,4
DHW specific flow rate (ΔT=30K)
l/min
8,8
13,4
15,5
16,2
Qualification of domestic hot water - EN 13203-1
-
Electric power supply – voltage / frequency
V - Hz
230 - 50
230 - 50
230 - 50
230 - 50
Power mains supply fuse
A
3,15
3,15
3,15
3,15
Maximum power consumption
W
88
97
101
106
Pump absorption
W
50
50
50
50
Electric protection rating
IP
X5D
X5D
X5D
X5D
Net weight
kg
32,0
34,5
35,5
37,0
Natural gas consumption at maximum CH output (Value referred to 15
°C - 1013 mbar)
cu. m/h
1,27
2,51
2,79
3,22
Propane gas consumption at maximum CH output
kg/h
0,93
1,84
2,05
2,36
Maximum CH working temperature
°C
83
83
83
83
Maximum DHW working temperature
°C
62
62
62
62
Total capacity of expansion vessel
l
10
10
10
10
Maximum recommended system capacity (Maximum water temperatu-
re 83°C, expansion vessel pressure 1 bar)
l
200
200
200
200
Tab. 6 General specifications KC models
Содержание ITACA KC 24
Страница 8: ...8 7 Malfunctions possible causes and solutions 92 7 1 Troubleshooting 92...
Страница 69: ...Instructions for the installer 69 Fig 26 Available head KC KR KRB 24 Fig 27 Available head KC KR KRB 28...
Страница 97: ...97 Page left intentionally blank...
Страница 98: ...98 Page left intentionally blank...
Страница 99: ...99 Page left intentionally blank...