Instructions for the installer
48
Wall-mounted terminals
The final parts of air intake and flue gas venting terminals, both split and coaxial, feature a groove (A) to fix the external collar (see
Fig. 14 Wall-mounted terminal installation).
Insert the external collar into the terminal until reaching the groove.
Insert the terminal, from outside, making the external collar adhere to the wall. The terminal projection beyond the wall must be that
imposed by the collar forced position.
Insert the internal collar, from inside, until it adheres to the wall.
Any pipes, bends or other components must not be inserted at the passage through the wall.
A
A
Fig. 14 Wall-mounted terminal installation
Tile for pitched roofs
The tile for pitched roofs can be used on roofs with an inclination between 18° and 44° (see Fig. 15 Tile for pitched roofs).
Remove the roofing elements (tiles, pantiles,...) from the roof area where the tile for pitched roofs will be installed.
Position the tile on the roof.
Position the roofing elements (tiles, pantiles,...) in such a way that rainwater drains over them.
Fit the cap (A) on the tile. The cap can be fitted in 2 positions, according to the roof inclination.
Insert the flue from above through the tile.
1
8
°
2
9
°
4
4
°
2
9
°
1
2
A
Fig. 15 Tile for pitched roofs
Содержание ITACA KC 24
Страница 8: ...8 7 Malfunctions possible causes and solutions 92 7 1 Troubleshooting 92...
Страница 69: ...Instructions for the installer 69 Fig 26 Available head KC KR KRB 24 Fig 27 Available head KC KR KRB 28...
Страница 97: ...97 Page left intentionally blank...
Страница 98: ...98 Page left intentionally blank...
Страница 99: ...99 Page left intentionally blank...