20
1.11.
Parameter display
Press “Info” (a fig.1) to scroll the different parameter values. You can quit this function at any time by simply pressing the "Reset" button. Paragraph
3.2.15 describes the meaning of all parameters.
PaRameTeRS
deSCRIPTIon
P30 - TSP30
external temperature displaying (if an external probe is present).
P31
Flow temperature displaying.
P32
Calculated nominal flow temperature displaying.
If no external probe is installed, the flow temperature manually set on boiler will be displayed. If an external probe is installed, the flow
temperature boiler calculated through the curves on fig. 1 will be displayed.
P42
domestic hot water temperature displaying (for KC models).
P43
Return temperature displaying.
P44
Displaying of water temperature at the inlet of plate heat exchanger (model KC).
Water cylinder temperature displaying (for models KRB and KR with installed (optional) water cylinder probe installed).
P45
Flue gas temperature displaying.
P46
Solar collector temperature displaying (if the collector probe is installed).
P47
Solar valve temperature displaying (if the solar valve probe is installed)
.
Table 3 - Displayable parameters with “info” button