25
1.
Condensate trap
2.
Modulating gas valve
3.
Flow temperature twin probe
4.
Modulating fan
5.
Primary condensing exchanger
6.
Air-purging device
7.
Air intake duct
8.
Flue gas venting duct
9.
Flue gas analysis ports
10. Flue gas thermostat on venting duct
11. Flue gas thermostat on exchanger
12. Ignition/detection electrode
13. Expansion vessel
14. Fan management probe
15. Return temperature probe
16. 3-bar safety valve
17. Pressure sensor
18. Air-purging device
19. 3-speed circulation pump
20. Discharge cock
21. Automatic by-pass
S
Condensate drain
G Gas
m
CH system flow
F
Cold water (from water mains)
R
CH system return
fig. 8
Model KR
8
M
7
6
5
4
3
2
1
21
9
10
11
12
13
14
16
19
1 sifone raccogli condensa
2 valvola gas modulante
3 doppio sensore di temperatura di mandata
4
5
ventilatore modulante
6
7
scambiatore primario condensante
8
9
disareatore
10
condotto aspirazione aria
11
condotto evacuazione fumi
12
prese analisi fumi
13
termostato fumi su condotto d’evacuazione
14
termostato fumi su scambiatore
16
elettrodo di accensione e rilevazione
17
vaso d’espansione
18
sensore controllo ventilatore
19
disareatore
20
circolatore modulante
21
sensore di pressione
rubinetto di scarico
by-pass automatico
M mandata riscaldamento
G gas
F
ingresso acqua fredda
R ritorno riscaldamento
S scarico condensa
G
20
17
18
valvola di sicurezza 3 bar
15
15 sensore di temperatura di ritorno
S
F R
2.4.
operating data
Burner pressures reported in the following page must be verified after the boiler has been operating for 3 minutes.
KC 24
fuel type
CH
max.
heat input
[kW]
CH
heat output
(80-60°C)
[kW]
CH
heat output
(50-30°C)
[kW]
DHW
heat output
[kW]
Gas mains
pressure
[mbar]
Nozzle
[mm/100]
Diaphragm
diameter
[mm]
flue gas
Co
2
value
[%]
min.
max.
min.
max.
min.
max.
Natural gas G20
23.7
2.7
22.9
3.22
24.9
3.0
27.4
20
3.7
-
9.0 ÷ 9.3
Propane Gas G31
23.7
2.7
22.9
3.22
24.9
3.0
27.4
37
3.0
-
10.0
Table 6 - KC 24 adjustment rates
Domestic hot water supply ΔT 45°C = 8.9 l/min
Domestic hot water supply ΔT 40°C = 10 l/min
Domestic hot water supply ΔT 35°C = 11.5 l/min
Domestic hot water supply ΔT 30°C = 13.4 l/min
Domestic hot water supply ΔT 25°C = 16.1 l/min
*Note: water mixed at cock
KC 12
fuel type
CH
max.
heat input
[kW]
CH
heat output
(80-60°C)
[kW]
CH
heat output
(50-30°C)
[kW]
DHW
heat output
[kW]
Gas mains
pressure
[mbar]
Nozzle
[mm/100]
Diaphragm
diameter
[mm]
flue gas
Co
2
value
[%]
min.
max.
min.
max.
min.
max.
Natural gas G20
12.0
1.8
11.6
2.1
12.7
1.8
18.6
20
3.05
-
9.0 ÷ 9.3
Propane Gas G31
12.0
1.8
11.6
2.1
12.7
1.8
18.6
37
2.50
-
10.0 ÷ 10.3
Table 5 - KC 12 adjustment rates
Domestic hot water supply ΔT 45°C = 5.7 l/min
Domestic hot water supply ΔT 40°C = 6.5 l/min
Domestic hot water supply ΔT 35°C = 7.4 l/min
Domestic hot water supply ΔT 30°C = 8.6 l/min *
Domestic hot water supply ΔT 25°C = 10.3 l/min *
*Note: water mixed at cock
Содержание FORMENTERA KC 12
Страница 30: ...30 76 60 62 67 82 73 155 24 23 9 760 12 80 80 100 80 190 92 80 290 173 147 132 14 0DIMACAR18 fig 9...
Страница 62: ...62...
Страница 63: ...63...