26
0QFSBUJOHEBUB
Burner pressures reported in the following page must be verified after the boiler has been operating for 3 minutes.
CTFS-RTFS 24
Gas type
)FBU
input
[kW]
.BYIFBU
output
[kW]
.JOIFBU
output
[kW]
Gas mains pressure [mbar]
Nozzle diameter
[mm/100]
Burner pressure
[mbar]
min.
max.
Natural gas G20
25.5
23.7
11.1
20
1.35
3.2
12.2
Butane Gas G30
25.5
23.7
11.1
29
0.78
7.5
28.3
Propane Gas G31
25.5
23.7
11.1
37
0.78
7.6
34.2
Table 7 - CTFS-RTFS 24 adjustment rates
Domestic hot water supply ΔT 45°C = 7.7 l/min
Domestic hot water supply ΔT 40°C = 8.7 l/min
Domestic hot water supply ΔT 35°C = 9.9 l/min
Domestic hot water supply ΔT 30°C = 11.6 l/min *
Domestic hot water supply ΔT 25°C = 13.9 l/min *
*Note: water mixed at cock
Domestic hot water supply ΔT 45°C = 9.5 l/min
Domestic hot water supply ΔT 40°C = 10.7 l/min
Domestic hot water supply ΔT 35°C = 12.2 l/min
Domestic hot water supply ΔT 30°C = 14.2 l/min *
Domestic hot water supply ΔT 25°C = 17.0 l/min *
*Note: water mixed at cock
Domestic hot water supply ΔT 45°C = 7.5 l/min
Domestic hot water supply ΔT 40°C = 8.4 l/min
Domestic hot water supply ΔT 35°C = 9.6 l/min
Domestic hot water supply ΔT 30°C = 11.2 l/min *
Domestic hot water supply ΔT 25°C = 13.4 l/min *
*Note: water mixed at cock
CTFS-RTFS 28
Gas type
)FBU
input
[kW]
.BYIFBU
output
[kW]
.JOIFBU
output
[kW]
Gas mains pressure [mbar]
Nozzle diameter
[mm/100]
Burner pressure
[mbar]
min.
max.
Natural gas G20
30.5
28.6
12.0
20
1.35
2.7
12.4
Butane Gas G30
30.5
28.6
12.0
29
0.78
6.0
29.3
Propane Gas G31
30.5
28.6
12.0
37
0.78
8.1
36.3
Table 8 - CTFS-RTFS 28 adjustment rates
CTN-RTN 24
Gas type
)FBU
input
[kW]
.BYIFBU
output
[kW]
.JOIFBU
output
[kW]
Gas mains pressure [mbar]
Nozzle diameter
[mm/100]
Burner pressure
[mbar]
min.
max.
Natural gas G20
25.5
23.1
8.5
20
1.35
2.0
12.0
Butane Gas G30
25.5
23.1
8.5
29
0.78
4.5
28.0
Propane Gas G31
25.5
23.1
8.5
37
0.78
6.0
35.0
Table 5 - CTN-RTN 24 adjustment rates
Domestic hot water supply ΔT 45°C = 9,0 l/min
Domestic hot water supply ΔT 40°C = 10.1 l/min
Domestic hot water supply ΔT 35°C = 11.6 l/min
Domestic hot water supply ΔT 30°C = 13.5 l/min *
Domestic hot water supply ΔT 25°C = 16.2 l/min *
*Note: water mixed at cock
CTN-RTN 28
Gas type
)FBU
input
[kW]
.BYIFBU
output
[kW]
.JOIFBU
output
[kW]
Gas mains pressure [mbar]
Nozzle diameter
[mm/100]
Burner pressure
[mbar]
min.
max.
Natural gas G20
30.5
28.6
12.0
20
1.35
2.7
12.4
Butane Gas G30
30.5
28.6
12.0
29
0.78
6.0
29.3
Propane Gas G31
30.5
28.6
12.0
37
0.78
8.1
36.3
Table 6 - CTN-RTN 28 adjustment rates