EN - 33
4.5.2 RETURNING TO FACTORY PROGRAMMING
In PROGRAMMING select DEF. PROG. and press the knob. Select
to cancel the operation.
Press RESET to confirm the return to the factory programming.
4.6 PARAMETERS
From SIMPLE / PROGRAM / TEMPORARY menus, press the knob to access the MENU and then select PARAMETERS to adjust/set
the following parameters:
1.
WINDOW OPENING DETECTION (WINDOW):
enabled/disabled type function. In the factory setting this function is
disabled.
2.
ASC (Adaptive Start Control): e
nabled/disabled type function. In the factory setting this function is disabled. If this
parameter is enabled and the appliance is in PROGRAM mode, the electronics activates the radiator in advance (up to
2 hours) so as to ensure that the room reaches the set temperature at the desired time. ASC is displayed when
this parameter is enabled and has triggered, if it is enabled but has not triggered ASC is not displayed.
3. LANGUAGE:
allows selecting the language.
4.
PILOT WIRE:
enabled/disabled type function. In the factory setting this function is disabled.
FP is displayed when this parameter is enabled and has triggered, if it is enabled but has not triggered ASC is not
displayed. The Pilot Wire is the black wire inside the power cable, used in France for control from remote control unit
(see paragraph 2 “Electrical connections”).
5.
Temperature CALIBRATION:
allows calibrating the temperature probe (+/- 5 °C) if the
a m b i e n t
temperature shown on the radiator display is different from the temperature
measured in the room.
The display shows the ambient temperature measured by the radiator in the position where it is
installed and the possible calibration already set.
The temperature of a room is not uniform, therefore it is possible that the temperature measured
by the radiator is different from that of another position in the room. The calibration function allows
compensating this difference.
Before using this function, the radiator must operate for at least 6 hours to stabilise the ambient temperature.
Example 1 :
If the temperature set on the radiator is 20 °C but the temperature measured in the room is 22 °C, set the calibration to 2 °C.
Example 2 :
If the temperature set on the radiator is 20 °C but the temperature measured in the room is 18 °C, set the calibration to -2 °C.