10
25/50 Series 220 V 60 Hz/230 V 50 Hz Dispensers
6. Temporarily remove rear access panel
(Figs. 4, 5) from rear of dispenser.
7. Loosen junction box mounting screws. Lift
junction box and power cord up until cord and
mounting screws clear notches on rear panel of
dispenser. Remove Phillips head screws from
right side of junction box.
8. Rotate junction box 90 degrees so that screw
holes on right side of junction box align with
holes on rear dispenser panel. Resecure
junction box to dispenser using Phillips head
screws.
9. Place power cord inside dispenser and replace
access panel (Figs. 4, 5) to rear of dispenser.
Note:
For dispensers to be installed with utilities
connected through rear of dispenser, it may be
easier to make preliminary connections before
dispenser is set in place.
10. Apply a thick bead, approx. 7mm (1/4") diameter,
of NSF listed silicone sealant (Dow Corning
RTV-732 or equivalent) 7mm (1/4") inside
marked outline of dispenser.
11. Carefully position dispenser on counter.
12. Remove four screws securing splash panel to
front of dispenser and gently lay splash panel
on counter. (Water line to solenoid valve can be
disconnected from water inlet valve by pushing
in on release ring at end of inlet fi tting while
pulling on tubing.)
13. Secure dispenser to counter with four 10mm
(3/8") bolts (supplied by others).
14. Smooth excess sealant around outside of
dispenser.
15. Run water supply line from back of dispenser
through utility knock-out (Figs. 4, 5F) or up
through counter cut-out. Connect water supply
line to 10mm (3/8") push-in fi tting on (Fig. 3G)
utility fl ange at bottom of dispenser.
16. Remove 19mm (3/4") drain connection plug
from either fi tting at rear of dispenser (Fig. 3L) or
internal fi tting (Fig. 3K), as appropriate. Connect
and run a dedicated drain line to wall or fl oor
drain. An air break should be provided.
17. Proceed with either remote or top mounted ice
machine connection instructions, as
appropriate (page 13, 14).
utility
connection
knock-out (F)
19mm
(3/4")
FPT
drain
access panel
20mm
149mm
375mm
267mm
(14.75")
(10.5")
(.8")
(5.875")
149mm
5.875"
267mm
(10.5")
162mm
(6.375")
375mm
(14.75")
ice
transport tube
knock-out (G)
utility
connection
knock-out (F)
19mm
(3/4")
FPT
drain
access panel
20mm
(.8")
Fig. 4 – Rear connections, countertop
models with integral ice machines
Fig. 5 – Rear connections, countertop
models with RIDE ice machines