25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
25
Normal operation – Stage 3
After the initial high current draw drops off, the gearmotor start relay contacts open, dropping out the start winding (or
start capacitor). As the compressor comes up to normal running speed, the compressor start relay contacts also open,
dropping out the start winding of the compressor. The icemaker is now in a normal icemaking mode. The icemaker will
begin to produce ice and continue to produce ice until the bin level control in the ice dispenser is satisfi ed. The PWR,
B-E, DR, C and WTR LEDs are all on.
GRD
L1
L1
L2
L2
L2
L2
L2
COMPRESSOR
FAN
DRIVE
DR
C
20M
60M
2ND
WTR
B-T
B-E
RESET
GRD
G
B
W
FAN
BLACK
WHITE
BLACK
BLACK
R
ORANGE
S
S
L
COMPRESSOR
C
RED
BLACK
BLACK
INPUT
POWER
WATER
SENSOR
CONTROL
BOARD
BLA
CK
24V
COMMON
LINE V
A
C
RED
RED
WHI
TE
BLA
CK
BIN T-STAT
BIN SIGNAL
FROM DISPENSER
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
WHITE
RED
WHITE
M
1
COMPRESSOR
SWITCH
PWR
BLACK
T.O.L.
BLACK
RED
HIGH PRESSURE
SAFETY SWITCH
M
WHI
TE
WHITE
BLUE
RELAY
START
T.O.L.
BLACK
4
2
3
YELLOW
GEAR MOTOR
T.O.L.
GEAR MOTOR
RED
START
RUN
RUN
START
START CAP.
BISON GEARMOTOR
LINIX GEARMOTOR
OR
Normal operation – Stage 4
Once the ice level control opens, the B-E LED goes out. After a 10 second delay the compressor LED (C), compressor
and fan motor go off. (Should the ice level control not remain open for 10 seconds, the icemaker will continue to run.)
The gearmotor continues to run and the DR LED remains lighted for 60 seconds. The purpose of this function is to
drive the remaining ice out of the evaporator and to boil off any refrigerant remaining in the evaporator. The bin timer
LED (BT) comes on, starting the twenty minute off cycle time delay.
GRD
L1
L1
L2
L2
L2
L2
L2
COMPRESSOR
FAN
DRIVE
DR
C
20M
60M
2ND
WTR
B-T
B-E
RESET
GRD
G
B
W
FAN
BLACK
WHITE
BLACK
BLACK
R
ORANGE
S
S
L
COMPRESSOR
C
RED
BLACK
BLACK
INPUT
POWER
WATER
SENSOR
CONTROL
BOARD
24V
COMMON
LINE V
A
C
RED
RED
WHI
TE
BLA
CK
BIN T-STAT
BIN SIGNAL
FROM DISPENSER
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
WHITE
RED
WHITE
M
1
COMPRESSOR
SWITCH
PWR
BLACK
T.O.L.
BLACK
RED
HIGH PRESSURE
SAFETY SWITCH
M
BLA
CK
WHI
TE
WHITE
BLUE
RELAY
START
T.O.L.
BLACK
4
2
3
YELLOW
GEAR MOTOR
T.O.L.
GEAR MOTOR
RED
START
RUN
RUN
START
START CAP.
BISON GEARMOTOR
LINIX GEARMOTOR
OR
Содержание Symphony 25HI400A
Страница 42: ...42 25CI400A W 25HI400A 50CI400A W 50HI400A Air cooled icemakers 1 7 3 16 5 4 8 14 13 15 2 9 6 10 11 12...
Страница 44: ...44 25CI400A W 25HI400A 50CI400A W 50HI400A Water cooled icemakers 1 16 17 2 3 4 18 5 10 8 13 6 12 14 11 9 15 7...
Страница 47: ...25CI400A W 25HI400A 50CI400A W 50HI400A 47...