background image

 38

Icemaker components

Water fi lter kits and cartridges

Part# Description 

00130229 

Follett QC4-FL4S water fi lter system (includes FL4S primary  cartridge and head, coarse pre-fi lter  

   

and head, pressure gauge, fl ushing valve; assembled and installed on mounting bracket)

00130245 

Follett FL4S primary replacement cartridge

00130211 

Everpure coarse pre-fi lter cartridge

501781 

Water pressure regulator (25 psi)

Ice machine cleaner

Part# Description 

00132001 

SafeCLEAN environmentally friendly icemaker cleaner, carton of 24 x 7 oz packets

Reference #

Description

Part #

1

Drier

502724

2

Coil, condenser

501187

3

Water sensor

502116

4

Float valve & reservoir

500504

Not shown

Elbow, 1/4", push-in

00121699

Not shown

Adapter, female thread to 1/4" push-in

00998716

Not shown

Fitting, plastic, fl oat valve (includes sleeve & stem)

502078

5

Compression nozzle, single drain

502221

6

Evaporator (see page 39 for detailed drawing)

Not shown

Shroud, condenser coil

501820

7

Drain pan, evaporator

502727

8

Valve, expansion, thermal

502726

Not shown

Valve, shut-off, water, brass

502222

9

Valve, shut-off, water, plastic

502921

10

Gearbox & motor, 115 V, 60 Hz (includes 307192)

00142034

Not shown

Strainer, water, threaded connections

500376

11

Strainer, water, push-in connections

502920

12

Fan blade

500474

13

Motor, fan, 115 V, 60 Hz

500672

14

Bracket, fan motor

501188

15

Overload, compressor, 115 V, 60 Hz

502782

16

Compressor, 115 V, 60 Hz

502731

17

Water line with Agion, evaporator

00141432

20

Bracket, fl oat valve

502383

21

Tube, ice transport

00168112

22

Insulation, ice tube, 12" (305 mm) required

501176

23

Bracket, gearmotor mounting

307192

24

Cord and plug, power

502776

25

Hi-pressure cut-out

502732

26

Clip, water shut-off valve

502922

Not shown

Elbow, water, 3/8"

502925

27

Tee, water, 1/4"

502923

Not shown

Gasket, ice hose

00977322

28

Pinch clamp

00988238

29

Drain tube with Agion, reservoir overfl ow

00980151

30

Drain tube with Agion, hopper/evaporator drain pan

00980144

Not shown

Tubing, plastic, 5/8 ID, bin drain tube before SN# B72959 (sold by the foot)

500623

Not shown

Adapter, 3/4" x 5/8" (Before SN# B72959)

00114199

Содержание Symphony 12 Series

Страница 1: ...r available with or without drain pan Following installation please forward this manual to the appropriate operations person 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 w...

Страница 2: ...ation Wiring diagram models with lever dispensing Wiring diagram models with SensorSAFE infrared dispensing Icemaker operational and diagnostic sequences Refrigeration cycle diagram Icemaker capacity...

Страница 3: ...g material inspect the equipment for concealed shipping damage If damage is found notify the shipper immediately and contact Follett Corporation so that we can help in the filing of a claim if necessa...

Страница 4: ...ter inlet 3 8 FPT 3 8 FPT Note Water shut off recommended within 10 feet 3 m of dispenser Drain to be hard piped and insulated Maintain at least 1 4 per foot 20 mm per 1 m run of slope Ventilation cle...

Страница 5: ...mm 305mm 305mm 366mm 407mm 21mm 2 51mm 16 14 4 12 0 8 1 5 12 15 9 18 4 1 26mm Fig 1 Counter information 0 437 12 mm diameter Installation Before you begin All dispensers must be installed level in bot...

Страница 6: ...Bottom exiting utilities countertop units Fig 4 bottom panel assembly 1 Carefully tip dispenser back to expose underside and block up in place 2 Screw legs shipped taped to drain pan of dispenser into...

Страница 7: ...t strength fasteners not included see Fig 6 3 Rough in water and drain lines Fig 10 4 Lift dispenser onto support bracket positioning unit so that hook on back of dispenser is captured by support brac...

Страница 8: ...Fig 6 Wall mounting dimensions bottom of dispenser outline of dispenser Caution Do NOT rest dispenser weight on bottom of support bracket Fig 7 Wall mount side view 22 5 572 mm 32 5 826 mm 18 5 470 m...

Страница 9: ...water and drain tubing 407mm 77mm 3 254mm 3 5 3 77mm 1 25 32mm MAX 77mm 89mm 77mm MIN 0 88 23mm MIN 16 10 3 3 nut support bracket screw bottom panel 3 4 FPT drain 3 8 OD push in water inlet Fig 8 Wal...

Страница 10: ...er Sensors in the panel use reflected infrared light to detect the presence of the container and send a signal to a control board which then activates the appropriate components for ice or water dispe...

Страница 11: ...cedures which follow should be performed at least as frequently as recommended below and more often if environmental conditions dictate Cleaning of the condenser can usually be performed by facility p...

Страница 12: ...e a large pan in bin storage area to catch ice or connect a separate ice transport tube to evaporator and divert ice into separate container 15 Fill reservoir almost to overflowing with sanitizing sol...

Страница 13: ...is ice is continuously removed by a slowly rotating 12 RPM auger The auger carries the ice upward into the cavity formed by the top bearing housing and the compression loop where it is compressed to r...

Страница 14: ...RESERVOIR SEE NOTE 1 HI PRESSURE SAFETY SWITCH P S COMPRESSOR OVER LOAD COMPRESSOR C R START RUN CONDENSER FAN BISON GEAR MOTOR NOTES 1 HIGH PRESSURE SAFETY SWITCH OPENS 425psi CLOSES 297psi SNAP SWI...

Страница 15: ...een suspended by activation of the clean switch The bin signal circuit is completed through the normally closed contacts of the bin thermostat and the bin signal switch When ice builds up around the b...

Страница 16: ...L2 L2 COMPRESSOR FAN DRIVE DR C 20M 60M 2ND WTR B T B E RESET GRD G B W FAN BLACK WHITE BLACK BLACK R ORANGE S S L COMPRESSOR C RED BLACK BLACK WHITE INPUT POWER WATER SENSOR CONTROL BOARD BLACK 24V...

Страница 17: ...RT T O L BLACK 4 2 3 YELLOW GEAR MOTOR T O L GEAR MOTOR RED START RUN RUN START START CAP BISON GEARMOTOR LINIX GEARMOTOR OR GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRIVE DR C 20M 60M 2ND WTR B T B E...

Страница 18: ...FAN DRIVE DR C 20M 60M 2ND WTR B T B E RESET GRD G B W FAN BLACK WHITE BLACK BLACK R ORANGE S S L COMPRESSOR C RED BLACK BLACK INPUT POWER WATER SENSOR CONTROL BOARD 24V COMMON LINE VAC RED RED WHITE...

Страница 19: ...ED HIGH PRESSURE SAFETY SWITCH M WHITE BLACK BLUE RELAY START T O L BLACK 4 2 3 YELLOW GEAR MOTOR T O L GEAR MOTOR RED START RUN RUN START START CAP WHITE BISON GEARMOTOR LINIX GEARMOTOR OR GRD L1 L1...

Страница 20: ...BLUE RELAY START T O L BLACK 4 2 3 YELLOW GEAR MOTOR T O L GEAR MOTOR RED START RUN RUN START START CAP WHITE BISON GEARMOTOR LINIX GEARMOTOR OR GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRIVE DR C 20M...

Страница 21: ...SON GEARMOTOR LINIX GEARMOTOR OR Diagnostic sequence Stage 10 If the water level in the float reservoir drops to an unacceptable level the WTR LED goes out shutting the icemaker off Also the BT LED co...

Страница 22: ...aker capacity 24 hrs Table 2 Compressor data Compressor current draw Air cooled Ambient air temp 60 F 15 6 C 70 F 21 1 C 80 F 26 7 C 90 F 32 2 C 100 F 37 8 C 6 3A 6 5A 6 7A 6 9A 7 1A Locked rotor amps...

Страница 23: ...reached close valves and both manifold and shut down the vacuum pump Allow the system to sit for approximately 20 minutes During this period the system pressure should not rise If the system pressure...

Страница 24: ...er cover inside dispenser cabinet off or ajar Dispense switch contacts burned shut Faulty or incorrectly positioned bin stat 1 Faulty water solenoid valve 2 Faulty dispense switch 3 Power switch off o...

Страница 25: ...replace board Problem Dispenses ice and or water continuously Board guide LEDs when illuminated indicate the following PWR board power CLN cleaning no dispensing cycle ICE ice dispensing activated WTR...

Страница 26: ...7 Superheat incorrect 8 Inefficient compressor 1 O ring seal broken Corrective action 1 Check that unit is plugged in circuit breakers are on 2 Adjust or replace ice level control 3 Check reservoir f...

Страница 27: ...ss or binding and replace if necessary 5 Replace gearmotor start relay 6 Ensure that ice contacts bin thermostat before backing ice up in transport tube Refer to dispenser manual for proper thermostat...

Страница 28: ...equence Wheelmotor removal 1 Remove dispense wheel and drive bar see above 2 Remove four 4 hopper support plate mounting screws and washers Fig 11 1 3 Move hopper assembly 1 2 13 mm to left 4 Remove f...

Страница 29: ...on nozzle from evaporator port Evaporator reassembly 1 Clean gearmotor boss output shaft and shaft well 2 Install drain pan and evaporator mounting base 3 Fill gear motor shaft well with food grade gr...

Страница 30: ...of unit and pull fan assembly toward front of unit c As fan assembly is being pulled toward front rotate assembly clockwise as shown above Fan removal Side panels Remove screw located on lower rear s...

Страница 31: ...Ice transport tube tube may extend a maximum of 1 4 6 mm into ice bin Top view 25 ice tube gasket ice tube retainer 50 TYP 3 76 mm capillary tube bracket Ice transport tube replacement 1 Push tube on...

Страница 32: ...s 502415 Not shown Fitting water inlet plastic 502924 7 Fitting water inlet brass 3 8 FPT 00137315 8 Lid top panel plastic serial numbers below D61292 502884 8 Lid top panel plastic serial numbers D61...

Страница 33: ...ce tube 2 25 high 00152017 See page 31 Retainer ice tube 00977314 See page 31 Gasket ice tube 502405 See page 31 Gasket ice tube 00977322 9 Assembly hopper with Agion includes drain fitting 502413 10...

Страница 34: ...ver 00976845 4 Boot dispense switch button 502418 5 Screw panel 00982421 6 Switch dispense 207670 7 Bracket lever support 00958793 8 Tube water solenoid 502420 9 Fitting bulkhead with nut 00976787 Not...

Страница 35: ...Not shown Splash panel without drain pan includes 2 Ty raps and 2 lenses 00981357 7 Splash panel includes 2 Ty raps and 2 lenses 00981332 8 Lens sensor each 502690 Not shown Splash panel ice only inc...

Страница 36: ...h Agion 00981233 3 Lever 502417 4 Thumbscrew 501100 5 Switch dispense 207670 6 Boot dispense switch button mounts over the dispense button 502418 7 Fastener dispense chute assembly 502057 8 Screws dis...

Страница 37: ...ting bracket see page 36 for exploded view 502421 7 Lens sensor each 502690 8 Ty rap sensor mounting 203611 9 Splash panel with drain pan includes 2 203611 and 2 502690 502675 10 Fastener dispense chu...

Страница 38: ...501820 7 Drain pan evaporator 502727 8 Valve expansion thermal 502726 Not shown Valve shut off water brass 502222 9 Valve shut off water plastic 502921 10 Gearbox motor 115 V 60 Hz includes 307192 00...

Страница 39: ...UTION HAZARDOUS MOVING OPERATE UNIT WITH PARTS DO NOT PANELS REMOVED OPERATE UNIT WITH 21 22 5 6 8 7 10 25 1 24 12 14 13 16 26 9 11 15 28 29 19 23 30 30 30 2 17 28 27 20 29 3 4 Rear view Right side vi...

Страница 40: ...d control circuit 115 V 60 Hz 502331 4 Water sensor 502116 5 Switch on off compressor 502392 6 Switch rocker power 502209 7 Switch rocker bin signal 502209 8 Switch cleaning SensorSAFE models 502409 9...

Страница 41: ...4 20 x 1 2 set of 4 501080 11 Mounting base evap includes 501063 502733 12 Bolt mounting base 502227 13 Gearbox motor includes 307192 00142034 Not shown Mounting base gearbox 502729 15 Compression no...

Страница 42: ...42...

Страница 43: ...43...

Страница 44: ...4 208595R18 Follett Corporation 8 12 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com SafeCLEAN SensorSAFE and Symphony are trademarks of Follett Corporatio...

Отзывы: