4
Specifi cations
Electrical
115 V, 60 Hz, 1 phase, 13.0A. Connect to 20A circuit, fuse or breaker.
Furnished with 6 ft (1.8m) power cord with a 90° hospital grade 5-20 plug.
Ambient
Air temp
100 F/38 C Max.
50 F/10 C Min. (Best performance below 80 F/27 C)
Water temp
90 F/32 C Max.
40 F/4 C Min. (Best performance below 70 F/21 C)
Water pressure
70 psi Max.
10 psi Min.
Plumbing
12CI400A 12HI400A
Dispenser drain
3/4" FPT
3/4" FPT
Water inlet
3/8" FPT
3/8" FPT
Note:
Water shut-off recommended within 10 feet (3 m) of dispenser. Drain to be hard-piped and insulated.
Maintain at least 1/4" per foot (20 mm per 1 m run) of slope.
Ventilation clearances
6" (153 mm) on right side of dispenser, 6" (153 mm) at top for ventilation and 12" (305 mm) at top recommended
for service.
Note:
Do NOT block right side air intake or top air exhaust.
Dry weight
175 lbs (79.4kg)
Dispenser front view
Dispenser side view
Dispenser rear view
Air
intake
air exhaust
air
intake
power cord
3/4" FPT drain
3/8" FPT
water inlet
16"
(407 mm)
22.625"
(575 mm)
32.5"
(826 mm)
4"
(102 mm)
18"
(458 mm)
23.5"
(597 mm)