10. Removing one at a time, transfer wiring from the original control
board to the replacement control board, ensuring each wire is
secured at the same location it was removed from .
11. Flip façade cover back into position on façade and reinstall 4
screws .
12. Remount façade to bayonet mounts .
13. Reconnect ground wire to grounding location on cabinet .
14. Reconnect all electrical and probe connections .
15. Plug in unit and power on, ensuring proper operation .
Reversing the door swing (requires a new door)
REFVAC20/25 units ship standard with a non heated right hinged door . To
change to a left hinged configuration requires a new door . For heated door
options other parts may be required . If the unit has a heated door option
consult technical service by calling (877) 612-5086 or +1 (610) 252-7301 .
Door gasket replacement
Fig. 32
1. Remove existing gasket from mounting track (Fig. 32) .
2. Verify mounting track is free of any remaining gasket material .
3. Align new gasket with mounting track and press firmly in place .
4. Open and close door, checking for proper gasket seal without
pinching against refrigerator .
Slide-out unit cooler
Fig. 33
Follett’s slide-out refrigeration system allows technicians to remove the
entire unit from the refrigerator top .
1. If necessary remove facade and upper side panels .
2. Remove four bolts securing unit cooler to refrigerator top (Fig. 33) .
3. Gently lift off cooler .