Alarm or Alert Notifications

 

§

If an alarm or event condition is detected and an alarm is engaged, 
an alert notification will appear in the left center of the screen with an 
explanation of the alert condition and a checkbox 

 at the bottom 

right of the alert box .

 

§

No further action can be taken on the User Interface until the alert 
condition is acknowledged and cleared by touching the checkbox 

 .

 

§

Mute

 

 

– Touch the

 

 icon to mute audible alarm for 10 minutes .

High/Low Alarm
This unit is equipped with a High and Low Temperature alarm that will give 
an audible and visual alarm immediately after the top probe falls out of 
range . The alarm will reappear every 10 minutes until the condition falls back 
into range . 

Fig. 15

Door Switch

 

§

This unit is equipped with a door switch that is located in the façade, and a magnet located on the top of the 
door . With the door closed, the switch reads closed . When the door is opened, the switch contacts open and 
turn on the LED lights .

Door Alarm

 

§

This unit is equipped with a door ajar alarm that is factory set for 1 minute . In the event the door switch reads 
open for longer than 60 seconds (default) an audible and visual alarm will occur . The alarm will clear when the 
door is closed . The door alarm activation time can be changed from 0-600 seconds in the Advanced Settings 
Menu under Door Open Alarm Delay .  

Power Alarm

 

§

This unit is equipped with a Power Alarm that will sound if the unit loses power for more than five minutes . The 
Power Loss Alarm box will display every five minutes, then the screen will sleep . An audible alarm will sound 
every 30 seconds during the power failure . An alarm box will be displayed when power is restored . The event 
log will record the exact time and date of the power loss and when the power was restored .

Start-up alarm delay

This unit has a 120 minute time delay between when the unit is energized to 
when the temperature alarms become active . This delay can be changed in 
parameters in the controller under 

Alarm Startup Delay .

Setting Alarms 

 

§

Alarming Settings control the conditions and timing of event and alarm 
conditions that result in audible and/or visual alerts .

 

§

To change the high alarm set point, touch the number displayed in the 
box to the right of the

 icon and use the keypad or 

UP and DOWN 

arrows to select an alarm value . Press 

 to accept or 

 to cancel .

 

§

To change the low alarm set point, touch the number displayed in the 
box to the right of the 

 icon and use the keypad or 

UP and DOWN 

arrows to select alarm value . Press 

 to accept or 

 to cancel .

 

§

Audible Alarm 

 

– Toggle between 

ON and OFF to engage and disengage the audible 

alarm function .

 

§

Mute

 

 

– Touch the

 

 icon to mute audible alarm for 10 minutes .

Fig. 16

HIGH

LOW

41.5 F

35.1 F

(1 - 10)

ON

3

OFF

Advanced Settings

Содержание REFVAC20-LB

Страница 1: ...0 25 PH REFVAC20 25 PD Order parts online www follettice com 01441492R00 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com healthcare Following installation...

Страница 2: ...Removing drawers 15 Removing slides 15 Network Enabled Device 15 Cleaning 15 Interior cleaning 15 Exterior cleaning 15 Annual cleaning 16 Defrosting 16 Service System Controls 17 Controller Operation...

Страница 3: ...epoxy coated baskets 6 epoxy coated baskets 6 stainless steel drawers 6 stainless steel drawers Exterior width 29 75 76 cm 29 75 76 cm 29 75 76 cm 29 75 76 cm 29 75 76 cm 29 75 76 cm Exterior depth 2...

Страница 4: ...ot exceed 60 RH A heated door is recommended for higher humidity ambients Clearances The top of the refrigerator must have 10 inches 25 4 cm of clear space above the refrigerator to ensure proper vent...

Страница 5: ...R00 REFVAC20 25 LB PH PD 5 Detail drawing REF20 30 5 78cm REF25 36 5 93cm 76 75 195cm 79 5 202cm 29 75 76cm 10 0 25 4cm Required Clearances 1 0 2 5 cm for power cord 2 0 2 5 cm if outlet directly behi...

Страница 6: ...cabinet Fig 1 2 6 Peel protective film from exterior walls of stainless cabinet Adjust self closing door Fig 2 1 Roll refrigerator to desired location and lock as many casters as possible Fig 2 1 2 If...

Страница 7: ...ation on the Certificate of Traceability supplied with your equipment at the time of purchase Recalibration or purchasing a new calibrated probe is not covered by the original equipment warranty To pu...

Страница 8: ...ng when blinking Refrigeration set points Sleep functions Centrigrade to Fahrenheit Functions and Settings Probe set points Alarming functions Alarm mute Reset Product temperature is displayed in the...

Страница 9: ...et point label and use the keypad or UP and DOWN arrows to select product temperature Press to accept or to cancel Sleep Temperature Display Toggle ON to hide the temperature reading immediately on th...

Страница 10: ...be changed from 0 600 seconds in the Advanced Settings Menu under Door Open Alarm Delay Power Alarm This unit is equipped with a Power Alarm that will sound if the unit loses power for more than five...

Страница 11: ...ipment warranty To purchase a new Probe with Certificate of Traceability please contact our Parts Department 1 877 612 5086 or partsales follettice com The temperature probes can be offset 9 9 to 9 9...

Страница 12: ...9 8F 3 1 13 01 45AM 39 7F 39 8F 3 1 13 02 00AM 39 8F 39 9F 3 1 13 02 30AM 40 0F 39 7F 3 1 13 02 15AM 39 9F 39 8F 3 1 13 03 00AM 41 8F 39 5F 3 1 13 02 45AM 41 9F 39 6F 3 1 13 03 15AM 40 7F 39 6F 3 1 13...

Страница 13: ...cel 1 Insert the storage device in the USB slot located to the left of the Touchscreen 2 Select the Graph icon along the bottom of the Touchscreen 3 Select the USB icon in the lower right hand corner...

Страница 14: ...6 Empty Done Edit Master Code User Access Codes Electronic Lock Override Insert key turn lock Remove panel Depress plunger with screwdriver Light To turn the interior light on or off touch the Light i...

Страница 15: ...e can cause staining and pitting of the stainless steel Disconnect power to unit by turning the power switch off located on the upper front facade panel and removing the power cord from the receptacle...

Страница 16: ...cleaning The side panel in front of condenser may be completely removed for easier cleaning by disconnecting facade and removing upper side panel See Face Removal for facade removal instructions 3 Ins...

Страница 17: ...in and cut out points of the cooling system For instance a unit running with a defaulted set point of 4 4 C 40 F will have the cooling system cut in at 6 6 C 44 F and cut out at 3 4 C 26 F according...

Страница 18: ...grounding strap when handling and installing control board Fig 31 1 Turn off power to unit and unplug 2 Disconnect electrical plugs and remove facade 3 Remove screw securing ground screw to refrigera...

Страница 19: ...hange to a left hinged configuration requires a new door For heated door options other parts may be required If the unit has a heated door option consult technical service by calling 877 612 5086 or 1...

Страница 20: ...ASS DOOR L1 GND N 120Vac 20Amp 1 2 3 5 20P ONLY PROBE t BOTTOM CABINET PROBE t TOP CABINET P4 P5 33 70 05 06 03 12 30 13 02 04 01 P1 P1 36 2 1 INTERIOR LIGHTING 24 VDC 1 A 63 64 61 62 60 01139856R04 U...

Страница 21: ...01441492R00 REFVAC20 25 LB PH PD 21 Refrigeration System HIGH PRESSURE VAPOR HIGH PRESSURE LIQUID LOW PRESSURE LIQUID LOW PRESSURE VAPOR FILTER DRIER COMPRESSOR EVAPORATOR CAPILLARY TUBE CONDENSER...

Страница 22: ...saver function will hide the home screen It will display a blank screen temperature or time and date Screen Saver Timer 0 seconds 0 to 600 seconds Amount of Time before the screen saver initiates Chan...

Страница 23: ...r Alarm 3 Alarm3 Reset 1 degrees 0 to 10 degrees Temperature difference to reset Alarm 3 General Alarm Reset Alarm Ringback 10 minutes 0 to 120 minutes Defines the time delay until the alarm will reso...

Страница 24: ...s Yes No Track events with log P1 Datalog No Yes No Log P1 to event log P2 Datalog No Yes No Log P2 to event log P4 Datalog Yes Yes No Log P4 to event log Defrost Manual Defrost No Yes No Force the un...

Страница 25: ...nutes Compressor on time when control probe error minutes Control Off Time mins UR REFVAC 8 0 0 to 120 0 minutes Compressor off time when control probe error Calibration Calibrate probes Calibrate pro...

Страница 26: ...ondenser fan motor with blade 01334127 Not shown Filter drier 01334069 4 Compressor with start components and drier 01334192 5 Start components 01334135 6 Evaporator with drier 01334044 7 Condenser wi...

Страница 27: ...n Key glass door 00945436 2 Lock glass door 00945444 Not shown Lock bracket 00939983 Not shown Door magnet kit 00939967 3 Right hand hinges with hardware 00996579 Not shown Left hand hinges with hardw...

Страница 28: ...43233 Not shown Alarm terminal assembly 01092022 4 Power switch 207360 5 Compressor relay 01223700 6 Facade reed switch 01132091 7 Touchscreen 01124221 Not shown Harness control to touchscreen 0106485...

Страница 29: ...Shell upper side REFVAC 00925933 Not shown Top ventilated cover 00991760 Not shown Back support 00991965 Not shown MOV assembly 01042258 Not shown RTD probe harness facade to control board 01106483 N...

Страница 30: ...et 01015817 Not shown Basket assembly REFVAC25 00939710 Not shown Basket assembly REFVAC20 00939728 6 Shelf REFVAC25 with supports 01460708 6 Shelf REFVAC20 with supports 01461268 7 Pilaster 00901173...

Страница 31: ...mos realizar un seguimiento de nuestro equipo y registrar el rendimiento de la maquinaria Por favor registre las garant as del equipo Follett en nuestro sitio web www follettice com support y seleccio...

Страница 32: ...01441492R00 Follett LLC 4 22 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com healthcare...

Отзывы: