Specifications
Electrical
§
Each ice machine and dispenser requires a separate circuit with electrical disconnect within 10 ft (6 m).
§
Equipment ground required.
§
Standard electrical – 115 V, 60 Hz, 1 phase.
§
Connect to a dedicated 15A circuit.
§
Maximum ice machine amperage – 11A each.
§
Cord and plug provided on ice machine.
Plumbing
§
3/8" FPT water inlet
§
3/4" MPT drain
§
3/8" FPT condenser inlet (water-cooled condenser only)
§
3/8" FPT condenser drain (water-cooled condenser only)
Notes:
§
Slope to drain of 1/4" per foot (20 mm per 1 m run) with a 1/2" min. is recommended.
§
Water shut-off recommended within 10 feet (3 m), drain to be hard piped and insulated.
§
Separate drains for ice machine and condenser. To prevent back flow, do NOT connect drains.
§
Follett recommends a Follett water filter system be installed in the ice machine inlet water line (standard capacity
#00130229, high capacity #00978957, carbonless high capacity #01050442).
Ambient
Air temperature*
100 F/38 C max.
50 F/10 C min. (best performance below 80 F/27 C)
Water temperature
†
90 F/32 C max.
45 F/10 C min. (best performance below 70 F/21 C)
Water pressure
70 psi max. (482 kPA)
10 psi min. (68 kPA)
Condenser water
temperature
90 F/32.2 C max.
45 F/7.2 C min
Condenser water
pressure
125 psi (862 kPA) max.
10 psi (68 kPA) min.
*
Ambient air temperature is measured at the air-cooled condenser coil inlet.
†
Ambient water temperature is measured in the ice machine reservoir.
Water usage (water-cooled condenser only)
§
0.25 gpm @ 50 F (10 C)
§
0.5 gpm @ 70 F (21 C)
§
1.25 gpm @ 90 F (32 C)
Shipping weight
§
160 lb (73 kg)
4