HCE1010A/W, HME1010A/W, HCE1410A/W, HME1410A/W
5
Specifications
Electrical
Each ice machine requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical:
§
HCE1010: 230/50/1 (6 ft (2m) cord)
§
HME1410: 230/50/1 (6 ft (2m) cord)
§
Amperage: 1010A/W - XA,
1410A/W - XA
Plumbing
WARNING
This equipment to be installed with adequate backflow protection to comply with applicable federal, state,
and local codes.
§
3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required
§
3/4" MPT drain
§
1/4" FPT condenser inlet (water-cooled condenser only)
§
1/4" FPT condenser drain (water-cooled condenser only)
Notes:
§
3/4" non-vented drain line must slope a minimum of 1/4" per foot (6 mm per 30.4 cm run).
§
Drain to be hard piped and insulated.
§
Separate drains for ice machine and condenser.
§
Water shut-off recommended within 10 feet (3m).
§
Water supply must have particle filtration. Follett recommends the filter system that has integral scale inhibitors.
(Follett item# 00130286).
§
Follett does not recommend the use of water softeners or bowl scale inhibitors.
Ambient
Air temperature
100 F/38 C max.
50 F/10 C min.
Water temperature
90 F/32 C max.
45 F/7 C min.
Water pressure – potable
70 psi max. (483 kPa)
10 psi min. (89 kPa)
Note: Water-cooled condenser pressure 150 psi (1034 kPa)
Heat rejection
1010
1410
Air-cooled
11,300 BTU/hr
16,000 BTU/hr
Water-cooled
12,800 BTU/hr
16,400 BTU/hr
Содержание Horizon Elite HCE1010A/W
Страница 17: ...HCE1010A W HME1010A W HCE1410A W HME1410A W 17 Wiring diagram...
Страница 34: ...34 HCE1010A W HME1010A W HCE1410A W HME1410A W 9 1 8 8 7 6 4 5 3 2 3 1410 1010 Air cooled assembly...
Страница 38: ...38 HCE1010A W HME1010A W HCE1410A W HME1410A W Electrical box 1 7 4 3 2 6 5 13 11 8 9 12 10...
Страница 42: ...42 HCE1010A W HME1010A W HCE1410A W HME1410A W Skins assembly 11 7 5 4 3 6 9 8 10 2 1 10...