10. Remove 3 screws (with 3/16" allen wrench) then 

remove auger and main housing together.

Note: Auger is sharp - wear protective gloves.

Fig. 18 

11. Rotate auger to align opening in auger flange with 

stream divider.

12. Pull out auger.:

Fig. 19 

13. Remove and discard the ceramic mating ring and 

shaft seal.

Содержание HCC1010A

Страница 1: ...on Elite Ice Machines Self contained 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com Following installation please forward this manual to the appropriate o...

Страница 2: ...diagram 13 Normal control board operation 14 DIP Switch Settings 14 Error faults 15 Soft errors 15 Run errors 15 Evaporator flushing sequence 15 Wiring diagram 16 Fan motor data 17 Mechanical System...

Страница 3: ...emoved To reduce risk of shock disconnect power before servicing Drain line must not be vented Water supply must have particle filtration Most ice machine cleaners contain citric or phosphoric acid wh...

Страница 4: ...condenser only 1 4 FPT condenser drain water cooled condenser only Notes Water shut off recommended within 10 feet 3m Water supply must have particle filtration Follett recommends the filter system th...

Страница 5: ...lbs 10 497 473 454 430 405 kg 60 1006 970 938 888 839 lbs 16 456 440 425 403 381 kg 70 917 898 874 830 778 lbs 21 416 407 396 376 353 kg 80 874 888 830 787 749 lbs 27 396 403 376 357 340 kg 90 831 807...

Страница 6: ...rilles must provide at least 250 sq in 1615 sq cm of open area Air cooled ice machines 18 458 mm minimum clearance between discharge and air intake grilles 1010 NEMA 6 15 1410 NEMA 6 20 A 22 51 57 2 c...

Страница 7: ...kly exterior care The exterior may be cleaned with a stainless cleaner such as 3M Stainless Steel Cleaner Polish or equivalent Monthly condenser cleaning air cooled icemaker only 1 Use a vacuum cleane...

Страница 8: ...cleaning cup until CLEANER FULL light comes on Do not overfill 4 Place one Sani Sponge in remaining sanitizing and cleaning solution and retain for Step 9 Note Do not use bleach to sanitize or clean t...

Страница 9: ...Disconnect coupling as shown Fig 6 8 Using disposable food service grade gloves insert dry Sani Sponge 9 Insert Sani Sponge soaked in SafeClean Plus from Step 4 10 Push both Sani Sponges down ice tra...

Страница 10: ...tube Fig 8 12 Reconnect coupling Press power switch ON Ice pushes Sani Sponges through ice transport tube Fig 9 13 Place a sanitary 2 gal or larger container in bin or dispenser to collect Sani Spong...

Страница 11: ...let The continuous extrusion process pushes the Chewblets through a transport tube into a dispenser or bin A solid state PC board controls and monitors the functionality of the ice machine In addition...

Страница 12: ...ning position of the flag is down and the switch is closed When the bin fills to the top and ice can no longer move through the tube the machine will force the shuttle flag up opening the switch and s...

Страница 13: ...ard will sense the activation During normal operation the water level rises and falls between the Normal High and Normal Low probes As water is consumed to make ice the level will fall until the Norma...

Страница 14: ...me of which will lock the machine off A flashing green light labeled POWER indicates power to the machine All other normal operation status indicators are covered as follows Ice machine disposition Op...

Страница 15: ...ine shuts down on a full bin and there has been 30 minutes of cumulative compressor run time the machine will purge before starting During this purge if water does not get below the low probe in the r...

Страница 16: ...16 HCC1010A W HCD1010A W HCC1410A W HCD1410A W Wiring diagram...

Страница 17: ...art winding 208 230 V 2 74 2 09 Compressor run winding 208 230 V 1 52 0 73 Gearmotor data Gearmotor current 2 0A 208 230 V Gearmotor torque out high amp trip point 2 8A 208 230 V Locked rotor amps 20A...

Страница 18: ...y 1 Press CLEAN button to purge evaporator Turn power OFF when LO WATER lights 2 Unscrew and disconnect transport tube from louvered docking assembly Fig 11 3 Remove gearbox insulation Fig 12 4 Discon...

Страница 19: ...move gear motor bolts 9 16 wrench 7 Remove gear motor and wipe auger shaft clean WIPE AUGER SHAFT Fig 15 8 Remove main housing insulation and shuttle insulation Fig 16 9 Remove front feed water tube f...

Страница 20: ...with 3 16 allen wrench then remove auger and main housing together Note Auger is sharp wear protective gloves Fig 18 11 Rotate auger to align opening in auger flange with stream divider 12 Pull out a...

Страница 21: ...ecess 16 Apply liquid hand soap to raised area of auger shaft and interior rubber portion of shaft seal before installing seal 17 Clean O ring groove Lubricate O ring with petrol gel and reinstall Car...

Страница 22: ...switch Align holes with pins Fig 23 1 and depress switch button Fig 23 2 to clear shuttle tab Fig 24 23 Install shuttle drain tube and front feed water tube Fig 24 Fig 25 24 Install main housing insul...

Страница 23: ...Slide gear motor onto auger and install gear motor bolts 9 16 wrench Fig 27 27 Connect gear motor wires Fig 28 28 Pry auger forward and rotate auger using 1 2 wrench to align keyways 29 Install key fu...

Страница 24: ...0A W HCC1410A W HCD1410A W Fig 30 31 Rotate retainer fork to align screw holes 32 Install screws to secure retainer fork Fig 31 33 Install gearbox insulation Fig 32 34 Connect transport tube to louver...

Страница 25: ...o rings Refrigeration system 1010 Refrigerant pressure data Air cooled condensers air 60 F 16 C 70 F 21 C 80 F 27 C 90 F 32 C 100 F 38 C Pressure psig discharge suction 190 32 225 34 258 36 292 39 32...

Страница 26: ...harge Suction PSIG Potable Water F C Condenser Water F C 50 10 60 16 70 21 80 27 90 32 50 10 290 32 290 32 290 32 290 33 290 33 psig 60 16 290 33 290 33 290 33 290 33 290 33 psig 70 21 290 33 290 33 2...

Страница 27: ...igerants Improper refrigeration servicing procedures will void the factory warranty Evacuation Evacuate the system to a level of 500 microns When the 500 micron level is reached close all valves Allow...

Страница 28: ...lity causing ice to jam auger 2 Damaged shuttle mechanism 3 Intermittent drive output from PC board Evaporator will freeze causing a HI AMPS error 4 Gearmotor is unplugged 1 Clean ice machine Increase...

Страница 29: ...achine is not making ice Lo water 1 Water supply is insufficient 2 Low water pressure 3 Defective water feed solenoid valve Stuck in closed position 4 No water feed output from PC board 5 Plugged scre...

Страница 30: ...0A W HCC1410A W HCD1410A W Replacement parts Evaporator assembly 1 3 21 14 13 12 11 9 29 7 8 20 15 16 18 22 23 13 31 31 31 31 31 19 13 24 25 26 28 28 4 5 10 2 31 17 17 17 17 17 35 34 33 36 6 30 32 2 2...

Страница 31: ...alve shut off water 502921 21 Auger 1010 self contained includes seal key and auger hardware 01117928 1010 only 21 Auger 1410 self contained includes seal key and auger hardware 01117936 1410 only 22...

Страница 32: ...32 HCC1010A W HCD1010A W HCC1410A W HCD1410A W 8 1 7 7 6 5 6 4 3 2 3 1410 1010 Air cooled assembly...

Страница 33: ...ressure safety 00117077 4 Drier 01153683 5 Valve expansion thermal includes insulation and 2 clamps 01118942 6 Insulation TXV body and bulb 502830 7 Compressor 1010 220 V 60 Hz includes start run comp...

Страница 34: ...34 HCC1010A W HCD1010A W HCC1410A W HCD1410A W Water cooled assembly 4 13 7 6 7 9 12 17 10 5 1 3 2 15 13 14 16 8 11 4...

Страница 35: ...42 7 Insulation TXV body and bulb 502830 8 Condenser w c 1010 1410 01302843 9 Valve shut off water 502222 10 Coupling 206411 11 Ty rap 01305309 12 Fitting flared adapter 01302850 13 Compressor 1010 22...

Страница 36: ...36 HCC1010A W HCD1010A W HCC1410A W HCD1410A W Electrical box 1 7 4 3 2 6 5 13 11 8 9 12 10...

Страница 37: ...1010 01302900 1010 only 5 Relay compressor starting 220 V 60 Hz 1410 01302918 1410 only 6 Contactor 220 V 60 Hz 01302926 7 Capacitor compressor starting 220 V 60 Hz 1010 01302934 1010 only 7 Capacitor...

Страница 38: ...10A W HCD1010A W HCC1410A W HCD1410A W Integration kit top mount and RIDE remote ice delivery 1 11 2 2 13 10 12 4 5 7 8 12 1 11 10 2 9 4 5 6 7 8 2 6 3 3 RIDE model configuration Top mount configuratio...

Страница 39: ...ncludes 10 3 m of tube and insulation 00171397 Not shown Integration kit drop in 00145334 Not shown Integration kit Cornelius PR150 00144774 Not shown Integration kit Vision does not include ice tube...

Страница 40: ...40 HCC1010A W HCD1010A W HCC1410A W HCD1410A W Skins assembly 11 7 5 4 3 6 9 8 10 2 1 10...

Страница 41: ...e clamp 500377 8 Plate strain relief 00192070 9 Louvered docking assembly 1010 includes strain relief plate bulkhead fitting 01119015 1010 only 9 Louvered docking station 1410 includes strain relief p...

Страница 42: ...mento realizar hoy mismo el registro En el formulario incluimos un espacio en blanco para sus comentarios y opiniones Inf rmenos sobre su experiencia para que podamos incorporarla a nuestros continuos...

Страница 43: ...Fazemos votos de que o nosso equipamento cumpra ou exceda as suas expectativas dado que temos por objetivo fornecer produtos e servi os de elevado valor que mere am a sua total satisfa o Pedimos lhe...

Страница 44: ...installationen genomf rs enligt fabrikens anvisningar s att din utrustning arbetar med h gsta effektivitet Follett LLC ansvarar inte f r f ljdskador kostnader avgifter eller f rluster som orsakats av...

Отзывы: