background image

4

Welcome to Follett

Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and 
outstanding after-the-sale support. To ensure that this equipment delivers the same degree of service, we ask 
that you review the installation manual (provided as a separate document) before beginning to install the unit. 
Our instructions are designed to help you achieve a trouble-free installation. Should you have any questions or 
require technical help at any time, please call our technical service group at (800) 523-9361 or (610) 252-7301.

Before you begin

After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage 
is found, notify the shipper immediately and contact Follett Corporation so that we can help in the filing of a claim, 
if necessary.

Check your paperwork to determine which model you have. Follett model numbers are designed to provide information 
about the type and capacity of Follett equipment. Following is an explanation of the different model numbers in the 
1000 series.

Horizon Series Icemaker Model Number Configurations

A Air-cooled, 

self-contained

W Water-cooled, 

self-contained

Air-cooled, remote condensing unit

Air-cooled, no condensing unit for

 

connection to parallel rack system

A

V

S

C

1000

HC

HC Horizon
 Chewblet

®

D  Low side 115/60/1
 Condenser 

208-230/60/1

 

(remote condensing only)

C 208-230/60/1

 (self-contained 

only)

E 230/50/1

 (self-contained 

only)

Icemaker

Model Series

Voltage

Capacity

Model Series

Condenser

V Vision™
H Harmony™
B Ice 

storage

 bin
J Drop-in

1000 up to
 1036 

lbs 

 (471kg)
1400 up to
 1450 

lbs 

 (658kg)

S Satellite-fill™
T Top-mount 

Application

Configuration

Chewblet is a registered trademark of  Follett Corporation, registered in the US.

 

CAUTION

•  Warranty does not cover exterior or outside installations.

•  Moving parts. Do not operate with front cover removed.

•  Hot parts. Do not operate with cover removed.

•  To reduce risk of shock, disconnect power before servicing.

•  Most ice machine cleaners contain citric or phosphoric acid, which can cause skin irritation. Read caution 

label on product and follow instructions carefully.

•  Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.

•  Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.

Содержание HCC1000A

Страница 1: ...Lane Easton PA 18040 USA Toll free 800 523 9361 610 252 7301 Fax 610 250 0696 www follettice com Following installation please forward this manual to the appropriate operations person Operation and Se...

Страница 2: ...must be returned in Follett packaging If the packaging has been damaged or discarded Follett will forward at the customer s expense new packaging Note Return freight charges are the responsibility of...

Страница 3: ...ication Compressor refrigerant solenoid output Wiring diagram Compressor data Gearmotor data Resistance of windings Mechanical system Evaporator disassembly Evaporator reassembly Refrigeration system...

Страница 4: ...eries Horizon Series Icemaker Model Number Configurations A Air cooled self contained W Water cooled self contained R Air cooled remote condensing unit N Air cooled no condensing unit for connection t...

Страница 5: ...temperature 90 F 32 C max 45 F 7 C min Water pressure potable 70 psi max 483 kPa 10 psi min 89 kPa Note Water cooled condenser pressure 150 psi 1034 kPa Heat rejection Air cooled rejects 11 000 BTU hr...

Страница 6: ...of open area Air cooled model HCC1000A icemakers 18 458mm minimum clearance between discharge and air intake grilles G L2 L1 Front View Side View Back View Air intake 21 05 535mm 23 50 597mm 21 28 54...

Страница 7: ...ss cleaner such as 3M Stainless Steel Cleaner Polish or equivalent Monthly condenser cleaning air cooled icemaker only 1 Use a vacuum cleaner or stiff brush to carefully clean condenser coils of air c...

Страница 8: ...I WATER light comes on Fig 2 Note Do not use bleach to sanitize or clean the icemaker HI WATER Fig 2 12 Fig 3 LO WATER N A E L C Fig 4 3 Replace cover on cleaning cup Wait until machine restarts Machi...

Страница 9: ...I SANITIZER Fill until HI WATER light comes on Fig 5 Note Do not use bleach to sanitize or clean the icemaker 6 Replace cover on cleaning cup Wait until machine restarts Machine will sanitize then flu...

Страница 10: ...ng disposable food service grade gloves insert dry Sani Sponge kit part 00132068 Next insert Sani Sponge soaked in Nu Calgon IMS II sanitizer solution Push both Sani Sponges down ice transport tube wi...

Страница 11: ...power switch ON Ice pushes Sani Sponges through tube Fig 11 12 Place a sanitary 2 gallon or larger container in bin or dispenser to collect Sani Sponges and ice for 10 minutes Collect 5 5 lbs of ice f...

Страница 12: ...ion process pushes the Chewblets through a transport tube into a dispenser or bin A solid state PC board controls and monitors the functionality of the ice machine In addition to sequencing electrical...

Страница 13: ...and falls between the Normal High and Normal Low sensors As water is consumed to make ice the level will fall until the Normal Low sensor is exposed triggering the water feed solenoid on Water will f...

Страница 14: ...ion and auger drive systems immediately shut down Note The fan motor will continue to run for 10 minutes to cool condenser The TIME DELAY light comes on initiating the time delay period When the time...

Страница 15: ...er feed solenoid will not be on The alarm will turn off should water recede from the sensor LO WATER During operation the water level cycles between the normal low and normal high sensors Should the w...

Страница 16: ...RAY PAIR HI PRESS HIGH PRESSURE OPENS EXCESS P 2 PE OPEN 425 PSI CLOSE 295 PSI K1 C NO L1 J7 J4 J5 MOTOR FAN J17 J18 J2 BRN BLU 1 2 3 J50 6 Amp Max 1 2hp Max NO C K3 J6 M2 M1 2 12 9 1 3 GRN 34 CB1 COM...

Страница 17: ...7 6A Water cooled Condenser water temp 50 F 10 C 60 F 16 C 70 F 21 C 80 F 27 C 90 F 32 C 6 5A 6 6A 6 8A 7 3A 7 5A Locked rotor amps 54 Gearmotor data Brother Gearmotor current 2 8A nominal Locked rot...

Страница 18: ...move stream divider as shown 3 Unplug and remove gearmotor as shown 4 Remove all traces of anti seize compound or petrol gel from the auger shaft Fig 13 Fig 14 Fig 15 5 Unscrew and disconnect transpor...

Страница 19: ...Fig 16 8 Loosen nut on V band clamp and remove 9 Remove V band clamp from front of evaporator 10 Remove main housing as shown Fig 17 11 Remove and discard mating ring and seal 12 Carefully remove aug...

Страница 20: ...iquid soap in the area shown and slip on seal and spring Note Do not touch the sealing surfaces Use cardboard disk to install Fig 20 5 Reinstall main housing as shown Fig 18 Evaporator reassembly 1 Re...

Страница 21: ...king sure that insulation is properly seated between gearmotor and main housing as shown 16 Firmly tighten four gearmotor bolts in place removed for clarity Note Shuttle housing Fig 21 6 Orient auger...

Страница 22: ...21 Lubricate body of stream divider with petrol gel and reinstall 22 Plug gearmotor power cord into electrical box Fig 24 17 Insert a bolt into the auger shaft and finger tighten 18 Using a wrench ro...

Страница 23: ...igeration system diagram Air cooled condensers air 60 F 16 C 70 F 21 C 80 F 27 C 90 F 32 C 100 F 38 C Pressure psig discharge suction 217 29 250 32 284 35 325 39 366 43 Water cooled condensers water 6...

Страница 24: ...factory warranty Evacuation Evacuate the system to a level of 500 microns When the 500 micron level is reached close all valves Allow the system to sit for approximately 20 minutes During this period...

Страница 25: ...the flag is down out of the sensor When the bin fills to the top and ice can no longer move through the tube the machine will force the shuttle flag up into the sensor shutting the machine off The sh...

Страница 26: ...I WATER CPU LO WATER POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SERVICE HI AMPS HI PRESS DRAIN CLOG HI WATER CPU LO WATER POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SER...

Страница 27: ...s POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SERVICE HI AMPS HI PRESS DRAIN CLOG HI WATER CPU LO WATER POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SERVICE HI AMPS HI PRE...

Страница 28: ...ent parts Evaporator assembly Order parts online www follettice com 8 9 12 11 10 37 28 39 40 23 34 38 41 33 29 35 17 18 18 31 30 26 23 24 25 24 24 27 23 36 32 23 13 14 15 16 1 3 19 17 23 28 18 5 20 21...

Страница 29: ...130674 21 Gasket sanitizer 00124032 22 Cap sanitizer includes 00124032 00130880 23 Tubing water 3 8 OD 502719 24 Tubing water 1 4 OD 502079 25 Hardware mounting evaporator cap 00130989 26 Solenoid wat...

Страница 30: ...Air cooled assembly 12 11 5 6 4 1 2 3 8 7 10 9 30 Order parts online www follettice com...

Страница 31: ...box support 00156035 5 Cut out high pressure safety 00117077 6 Insulation bulb TXV 00106534 7 Drier 502724 8 Valve expansion thermal includes 502830 and 00106534 00130997 9 Insulation TXV 502830 10 Ha...

Страница 32: ...32 Water cooled assembly 5 11 12 13 13 10 6 17 18 1 4 2 8 7 9 15 16 15 12 14 3 11 Order parts online www follettice com...

Страница 33: ...bulb TXV 00106534 7 Drier 502724 8 Valve expansion thermal includes 502830 and 00106534 00130997 9 Insulation TXV 502830 10 Condenser w c 00117234 11 Elbow water 90 00129478 12 Valve shut off water 50...

Страница 34: ...34 Electrical box 1 2 6 4 5 7 8 9 10 3 15 14 13 12 11 Order parts online www follettice com...

Страница 35: ...lamp run capacitor 00133603 6 Relay compressor starting includes wire harness 00161810 7 Contactor 00117010 8 Capacitor compressor starting 00133504 9 Cap capacitor 00133587 10 Bracket capacitor 20762...

Страница 36: ...36 Integration kit top mount and Satellite fill Order parts online www follettice com 1 2 3 4 5 6 1 12 14 15 16 17 13 12 13 2 4 3 3 4 9 4 3 10 7 8...

Страница 37: ...be 10 3m 502522 9 Ice transport tube 20 6m 502523 10 Insulation transport tube 501176 11 Coupling assembly 00131003 12 Ring locking 00126508 13 Gasket coupling 00126532 14 Coupling fill tube 00126466...

Страница 38: ...X BRAN CH CIRCU IT FUSE SIZE MIN BRAN CH CIRCU IT AMPA CITY DES IGN PRE SSU RE HIG H SID E AMP S AMP S C R REF RIG ERA NT East on Pen nsy lvan ia VOL TS CHA RGE LOW SID E HZ PAR T NO COR POR ATIO N SE...

Страница 39: ...ater inlet 502924 7 Elbow water inlet 502925 8 Nut ice tube coupling 00122804 9 Retainer ice tube 00129270 10 O ring ice tube 00123836 11 Coupling ice tube 00123091 12 Power cord 240V 00134445 13 Louv...

Страница 40: ...129932R06 02 07 801 Church Lane Easton PA 18040 USA Toll free 800 523 9361 610 252 7301 Fax 610 250 0696 www follettice com Chewblet is a registered trademark of Follett Corporation registered in the...

Отзывы: