background image

7

Operation

Cleaning and preventive maintenance (all models)

Note: 

Do not use bleach to sanitize or clean the icemaker.

Preventive maintenance

Periodic cleaning of Follett’s icemaker system is required to ensure peak performance and delivery of clean, 
sanitary ice. The recommended cleaning procedures that follow should be performed at least as frequently as 
recommended, and more often if environmental conditions dictate.

Cleaning of the condenser can usually be performed by facility personnel. Cleaning of the icemaker system, 
in most cases, should be performed by your facility’s maintenance staff or a Follett authorized service agent. 
Regardless of who performs the cleaning, it is the operator’s responsibility to see that this cleaning is performed 
according to the schedule below. Service problems resulting from lack of preventive maintenance will not be 
covered under the Follett warranty.

Weekly exterior care

The exterior may be cleaned with a stainless cleaner such as 3M Stainless Steel Cleaner & Polish or equivalent.

Monthly condenser cleaning (air-cooled icemaker only)

  1.  Use a vacuum cleaner or stiff brush to carefully clean condenser coils of air-cooled icemakers to ensure

optimal performance.

  2.  When reinstalling counter panels in front of remote icemakers, be sure that ventilation louvers line up with

condenser air duct.

Semi-annual evaporator cleaning (every 6 months) 

 

WARNING

•  Wear rubber gloves and safety goggles (and/or face shield) when handling ice machine cleaner or sanitizer

.

 

CAUTION

•  Use only Follett approved SafeCLEAN™ Cleaner (part #00132001) and NU-CALGON IMS-II SANITIZER. 

•  Do not mix Cleaner and Sanitizer solutions together.

•  DO NOT USE BLEACH. 

•  It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling.

•  Read and understand all labels printed on packaging before use.

Note: Complete procedure for cleaning an sanitizing MUST be followed. Ice must be collected for 10 
minutes before putting ice machine back into service.

  1.  To clean – Remove cover. Press the CLEAN  

 

button. The machine will drain. Wait for the LO  

 

WATER light to come on (Fig. 1).

LO WATER

CL

EA

N

Fig. 1

Содержание HCC1000A

Страница 1: ...Lane Easton PA 18040 USA Toll free 800 523 9361 610 252 7301 Fax 610 250 0696 www follettice com Following installation please forward this manual to the appropriate operations person Operation and Se...

Страница 2: ...must be returned in Follett packaging If the packaging has been damaged or discarded Follett will forward at the customer s expense new packaging Note Return freight charges are the responsibility of...

Страница 3: ...ication Compressor refrigerant solenoid output Wiring diagram Compressor data Gearmotor data Resistance of windings Mechanical system Evaporator disassembly Evaporator reassembly Refrigeration system...

Страница 4: ...eries Horizon Series Icemaker Model Number Configurations A Air cooled self contained W Water cooled self contained R Air cooled remote condensing unit N Air cooled no condensing unit for connection t...

Страница 5: ...temperature 90 F 32 C max 45 F 7 C min Water pressure potable 70 psi max 483 kPa 10 psi min 89 kPa Note Water cooled condenser pressure 150 psi 1034 kPa Heat rejection Air cooled rejects 11 000 BTU hr...

Страница 6: ...of open area Air cooled model HCC1000A icemakers 18 458mm minimum clearance between discharge and air intake grilles G L2 L1 Front View Side View Back View Air intake 21 05 535mm 23 50 597mm 21 28 54...

Страница 7: ...ss cleaner such as 3M Stainless Steel Cleaner Polish or equivalent Monthly condenser cleaning air cooled icemaker only 1 Use a vacuum cleaner or stiff brush to carefully clean condenser coils of air c...

Страница 8: ...I WATER light comes on Fig 2 Note Do not use bleach to sanitize or clean the icemaker HI WATER Fig 2 12 Fig 3 LO WATER N A E L C Fig 4 3 Replace cover on cleaning cup Wait until machine restarts Machi...

Страница 9: ...I SANITIZER Fill until HI WATER light comes on Fig 5 Note Do not use bleach to sanitize or clean the icemaker 6 Replace cover on cleaning cup Wait until machine restarts Machine will sanitize then flu...

Страница 10: ...ng disposable food service grade gloves insert dry Sani Sponge kit part 00132068 Next insert Sani Sponge soaked in Nu Calgon IMS II sanitizer solution Push both Sani Sponges down ice transport tube wi...

Страница 11: ...power switch ON Ice pushes Sani Sponges through tube Fig 11 12 Place a sanitary 2 gallon or larger container in bin or dispenser to collect Sani Sponges and ice for 10 minutes Collect 5 5 lbs of ice f...

Страница 12: ...ion process pushes the Chewblets through a transport tube into a dispenser or bin A solid state PC board controls and monitors the functionality of the ice machine In addition to sequencing electrical...

Страница 13: ...and falls between the Normal High and Normal Low sensors As water is consumed to make ice the level will fall until the Normal Low sensor is exposed triggering the water feed solenoid on Water will f...

Страница 14: ...ion and auger drive systems immediately shut down Note The fan motor will continue to run for 10 minutes to cool condenser The TIME DELAY light comes on initiating the time delay period When the time...

Страница 15: ...er feed solenoid will not be on The alarm will turn off should water recede from the sensor LO WATER During operation the water level cycles between the normal low and normal high sensors Should the w...

Страница 16: ...RAY PAIR HI PRESS HIGH PRESSURE OPENS EXCESS P 2 PE OPEN 425 PSI CLOSE 295 PSI K1 C NO L1 J7 J4 J5 MOTOR FAN J17 J18 J2 BRN BLU 1 2 3 J50 6 Amp Max 1 2hp Max NO C K3 J6 M2 M1 2 12 9 1 3 GRN 34 CB1 COM...

Страница 17: ...7 6A Water cooled Condenser water temp 50 F 10 C 60 F 16 C 70 F 21 C 80 F 27 C 90 F 32 C 6 5A 6 6A 6 8A 7 3A 7 5A Locked rotor amps 54 Gearmotor data Brother Gearmotor current 2 8A nominal Locked rot...

Страница 18: ...move stream divider as shown 3 Unplug and remove gearmotor as shown 4 Remove all traces of anti seize compound or petrol gel from the auger shaft Fig 13 Fig 14 Fig 15 5 Unscrew and disconnect transpor...

Страница 19: ...Fig 16 8 Loosen nut on V band clamp and remove 9 Remove V band clamp from front of evaporator 10 Remove main housing as shown Fig 17 11 Remove and discard mating ring and seal 12 Carefully remove aug...

Страница 20: ...iquid soap in the area shown and slip on seal and spring Note Do not touch the sealing surfaces Use cardboard disk to install Fig 20 5 Reinstall main housing as shown Fig 18 Evaporator reassembly 1 Re...

Страница 21: ...king sure that insulation is properly seated between gearmotor and main housing as shown 16 Firmly tighten four gearmotor bolts in place removed for clarity Note Shuttle housing Fig 21 6 Orient auger...

Страница 22: ...21 Lubricate body of stream divider with petrol gel and reinstall 22 Plug gearmotor power cord into electrical box Fig 24 17 Insert a bolt into the auger shaft and finger tighten 18 Using a wrench ro...

Страница 23: ...igeration system diagram Air cooled condensers air 60 F 16 C 70 F 21 C 80 F 27 C 90 F 32 C 100 F 38 C Pressure psig discharge suction 217 29 250 32 284 35 325 39 366 43 Water cooled condensers water 6...

Страница 24: ...factory warranty Evacuation Evacuate the system to a level of 500 microns When the 500 micron level is reached close all valves Allow the system to sit for approximately 20 minutes During this period...

Страница 25: ...the flag is down out of the sensor When the bin fills to the top and ice can no longer move through the tube the machine will force the shuttle flag up into the sensor shutting the machine off The sh...

Страница 26: ...I WATER CPU LO WATER POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SERVICE HI AMPS HI PRESS DRAIN CLOG HI WATER CPU LO WATER POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SER...

Страница 27: ...s POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SERVICE HI AMPS HI PRESS DRAIN CLOG HI WATER CPU LO WATER POWER LOW BIN AUGER ON REFRIG ON PURGE TIME DELAY CLEANING SERVICE HI AMPS HI PRE...

Страница 28: ...ent parts Evaporator assembly Order parts online www follettice com 8 9 12 11 10 37 28 39 40 23 34 38 41 33 29 35 17 18 18 31 30 26 23 24 25 24 24 27 23 36 32 23 13 14 15 16 1 3 19 17 23 28 18 5 20 21...

Страница 29: ...130674 21 Gasket sanitizer 00124032 22 Cap sanitizer includes 00124032 00130880 23 Tubing water 3 8 OD 502719 24 Tubing water 1 4 OD 502079 25 Hardware mounting evaporator cap 00130989 26 Solenoid wat...

Страница 30: ...Air cooled assembly 12 11 5 6 4 1 2 3 8 7 10 9 30 Order parts online www follettice com...

Страница 31: ...box support 00156035 5 Cut out high pressure safety 00117077 6 Insulation bulb TXV 00106534 7 Drier 502724 8 Valve expansion thermal includes 502830 and 00106534 00130997 9 Insulation TXV 502830 10 Ha...

Страница 32: ...32 Water cooled assembly 5 11 12 13 13 10 6 17 18 1 4 2 8 7 9 15 16 15 12 14 3 11 Order parts online www follettice com...

Страница 33: ...bulb TXV 00106534 7 Drier 502724 8 Valve expansion thermal includes 502830 and 00106534 00130997 9 Insulation TXV 502830 10 Condenser w c 00117234 11 Elbow water 90 00129478 12 Valve shut off water 50...

Страница 34: ...34 Electrical box 1 2 6 4 5 7 8 9 10 3 15 14 13 12 11 Order parts online www follettice com...

Страница 35: ...lamp run capacitor 00133603 6 Relay compressor starting includes wire harness 00161810 7 Contactor 00117010 8 Capacitor compressor starting 00133504 9 Cap capacitor 00133587 10 Bracket capacitor 20762...

Страница 36: ...36 Integration kit top mount and Satellite fill Order parts online www follettice com 1 2 3 4 5 6 1 12 14 15 16 17 13 12 13 2 4 3 3 4 9 4 3 10 7 8...

Страница 37: ...be 10 3m 502522 9 Ice transport tube 20 6m 502523 10 Insulation transport tube 501176 11 Coupling assembly 00131003 12 Ring locking 00126508 13 Gasket coupling 00126532 14 Coupling fill tube 00126466...

Страница 38: ...X BRAN CH CIRCU IT FUSE SIZE MIN BRAN CH CIRCU IT AMPA CITY DES IGN PRE SSU RE HIG H SID E AMP S AMP S C R REF RIG ERA NT East on Pen nsy lvan ia VOL TS CHA RGE LOW SID E HZ PAR T NO COR POR ATIO N SE...

Страница 39: ...ater inlet 502924 7 Elbow water inlet 502925 8 Nut ice tube coupling 00122804 9 Retainer ice tube 00129270 10 O ring ice tube 00123836 11 Coupling ice tube 00123091 12 Power cord 240V 00134445 13 Louv...

Страница 40: ...129932R06 02 07 801 Church Lane Easton PA 18040 USA Toll free 800 523 9361 610 252 7301 Fax 610 250 0696 www follettice com Chewblet is a registered trademark of Follett Corporation registered in the...