Installing countertop dispensers
1. Position dispenser in desired location, mark
dispenser outline on counter and remove
dispenser.
2. Drill four 10mm (3/8") holes in counter
(Fig. 2) to anchor dispenser to counter.
Note:
Follett countertop dispensers can
have any or all utilities run directly through
counter or out rear of dispenser. For
dispensers with any utilities exiting through
counter, make counter cut-out (Fig. 2)
3. If ice transport tube will exit out rear of
dispenser, remove ice transport tube knock-
out (Fig. 5G) from rear of dispenser.
Note:
Utility connections can be accessed
through front of dispenser by removing
stainless steel splash panel,
or by removing access panel (Figs. 4, 5)
on back of dispenser.
4. If any electric utilities or water line will be connected through rear of dispenser, remove utility knock-out
(Figs. 4, 5F) from rear of dispenser and install supplied protective grommet.
5. If power is to be supplied through counter cut-out, complete steps 6-9. If power is to be supplied through
rear of dispenser, proceed to step 10.
534mm (21")
512mm (20.125")
318mm
420mm
166mm
10mm (.375")
39mm (1.5")
12mm (.44")
267mm
229mm x 356mm
(9" X 14")
DRAIN PAN
cut-out
(10.5")
(12.5")
(16.5")
(6.5")
10mm
holes
(.375")
13mm
(.5")
(G) 10mm (3/8") FPT water inlet
(K) alternate 19mm (3/4") dispenser
drain location
(H) 10mm (3/8") FPT condenser
water inlet
drain pan
(L) 19mm (3/4") FPT dispenser drain
(J) 10mm (3/8") FPT condenser
water outlet
Dispensers with top mount icemakers cannot be mounted on legs. They must be bolted to
counter. Use gloves when lifting icemaker to protect hands from sheet metal edges.
!
Fig. 2 – Counter cut-out, all models
Fig. 3 – Top view, dispenser plumbing connections countertop