110CT425A/W, 110FB425A/W
15
SensorSAFE model troubleshooting guide
Problem
Action
SensorSAFE Board LED
Status
Corrective Action
PWR
CLN
ICE/
WTR
Does not
dispense ice
and/or water.
Check
LEDs on the
SensorSAFE
control board.
OFF
OFF
OFF
Check circuit breakers and power switch.
Restore power or replace defective switch.
ON
ON
OFF
Press clean switch on lower left side of electrical
enclosure to return board to normal operation.
Place cup
under drop
zone (in front
of lens).
ON
OFF
OFF
Troubleshoot appropriate lens/sensor
and replace if required (see lens/sensor
troubleshooting).
ON
OFF
ON
Verify power on appropriate output terminal
(WTR or WM) on control board and replace
board if required. If board tests okay,
troubleshoot appropriate dispenser component.
Dispenses ice
and/or water
continuously.
Check LEDs
on control
board.
ON
OFF
ON
Troubleshoot appropriate lens/sensor
and replace if required (see lens/sensor
troubleshooting).
ON
OFF
OFF
If there is power on any output terminal (WTR or
WM) on control board, replace board.