background image

01033729R05

© Follett LLC 5/18

Calgon is a licensed trademark distributed by Nu-Calgon, in the United States.
Dow Corning is a registered trademark of Dow Corning Corporation in the United States and other countries.
SafeCLEAN, SaniSponge, SensorSAFE, and Symphony Plus are trademarks of Follett LLC.

Follett is a registered trademarks of Follett LLC, registered in US.

801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com

Warranty Registration and Equipment Evaluation

Thank you for purchasing Follett ® equipment. Our goal is to deliver high value products and services that earn your complete 
satisfaction by delivering high-value products and services backed by outstanding customer and technical support. 
Please review the installation instructions thoroughly. It is important that the installation be performed to factory specifications 
so your equipment operates at its maximum efficiency.
Follett LLC will not be liable for any consequential damages, expenses, connecting or disconnecting charges, or any losses 
resulting from a defect of the machine. For full warranty details, visit our website www.follettice.com/productwarranties.
Registering your equipments helps Follett track your equipment's service history should you need to contact us for technical 
support, and your feedback helps us improve our products and services. Please visit www.follettice.com/support to complete 
the Warranty Registration form.
Should you have any questions, please contact Follett's technical support group at (877) 612-5086 or (610) 252-7301 and we 
will be happy to assist you.

Содержание 110CT425A

Страница 1: ...re that this equipment delivers that same degree of service review this guide carefully before you begin your installation Should you have need technical help please call our Technical Service group a...

Страница 2: ...r to unit must be disconnected first Follett recommends a Follett water filter system be installed in the ice machine inlet water line standard capacity 00130229 high capacity 00978957 carbonless high...

Страница 3: ...sure psi bar 70 5 Max 10 0 7 Min Ambient air temperature is measured at the air cooled condenser coil inlet Ambient water temperature is measured in the ice machine reservoir Plumbing 110CT with integ...

Страница 4: ...lines to 3 4 MPT dispenser drain fitting and 3 4 MPT ice machine drain fitting on back of dispenser 4 Run drain lines to wall or floor drain If ice machine drain fitting is below an intended wall drai...

Страница 5: ...ont cover by removing two screws at bottom corners of cover Lift cover slightly and pull forward 11 If dispenser is equipped with SensorSAFE remove protective plastic coating from dispense sensor labe...

Страница 6: ...pensers with any utilities exiting through counter make counter cut out Fig 2 3 For utilities exiting through bottom only a Make cut out as shown Fig 2 b Move drain fitting from back of dispenser and...

Страница 7: ...ion box 7 Rotate junction box 90 degrees so that screw holes on right side of junction box align with holes on rear dispenser panel Secure junction box to dispenser using Phillips head screws 8 Place...

Страница 8: ...e compartment top and side panels 3 Remove ice machine hold down bracket from front of ice machine compartment 4 Lift ice machine onto dispenser top and slide ice machine completely into position comp...

Страница 9: ...ce machines connect condenser water supply and drain lines to condenser fittings on ice machine 11 Turn on water supply and check for leaks 12 Plug dispenser power cord into 15A rated NEMA 5 15 circui...

Страница 10: ...ormed by your facility s trained maintenance staff or a Follett authorized service agent Regardless of who performs the cleaning it is the operator s responsibility to see that this cleaning is perfor...

Страница 11: ...ore proceeding If there is ice in the evaporator complete steps 2 7 using only hot water to remove the ice then begin Cleaning Procedure again 2 Remove front cover and turn OFF bin signal switch 3 Dis...

Страница 12: ...canister to hold coil securely against canister wall i Reinstall chilled water assembly on dispenser and tighten screw securing front bracket j Reconnect 3 4 19 mm drain line to chilled water canister...

Страница 13: ...racket of chilled water canister to bottom of dispenser hopper d Rotate canister clockwise to release front bracket then pull canister forward to disengage rear bracket e Remove chilled water coil fro...

Страница 14: ...ontacts burned shut 2 Debris preventing valve from closing 1 Replace water solenoid valve 2 Replace dispense switch 3 Check switch turn on or replace if faulty Water runs continuously 1 Faulty water s...

Страница 15: ...normal operation Place cup under drop zone in front of lens ON OFF OFF Troubleshoot appropriate lens sensor and replace if required see lens sensor troubleshooting ON OFF ON Verify power on appropria...