Displays (internal) (DLI-230 ANA)
Power on/off (stand-by)
green = on, red = stand-by, red flashing = fault, blue = sign
Network control
receive/send remote control LED
Displays (internal) (DLI-230 DAN)
Power on/off (stand-by)
-
Network control
-
CAAD Simulation data
Simulation data
EASE
[1] peak, 20 ms with band filtered pink noise in accordance with IEC 60268-2, one octave above the lowest cut-off frequency
[2] -10 dB under reflection-free half-space conditions
[3] horizontal x vertical at -6 dB
[4] net weight without optional extras
[5] further colours such as RAL Design or NCS only available on request
Performance Data DLI-230
U = 230 VAC
Conditions
Performance
Current (A)
Performance
Watt ohmsch
Performance VA
Standby
0.24
9.1
56
Idling time without
signal
0.25
11
[2]
60
Idling time with
Signal -50 dBV
0.28
26
65
Maximum mean
power
[1]
Beam Optimize,
Sin 200 Hz
1.08
240
248
[2]
Maximum mean
power
Beam Optimize,
Pink Noise
0.66
140
152
Maximum mean
power
Sin 200 Hz
1.44
300
334
Peak power
Sin 200 Hz, 1 s
2.08
460
480
Inrush current
5 A
<50 ms
[1]
optimized for speech intelligibility in reverberant acoustics (airports, railway stations, stadia etc.)
[2]
recommended values for calculating energy consumption