16
(3) Fault message contact (2x)
An error status can be reported via these open/closed contacts. The fault contact relay (2 x UM)
should be operated with a maximum of 50 V and 500 mA.
One of the two 3-pin Phoenix connectors can be used as a link!
(4) Fohhn-Net Input (2x)
The
DLI-130/230/330/430 AES
can be connected to the
Fohhn-Net
remote control network via these
3-pin Phoenix connectors
One of the two 3-pin Phoenix connectors can be used as a link!
(5) Switching contact
This 3-pin Phoenix connector serves as a switching contact for changing presets. This can be
configured in
Fohhn Audio Soft
(see Chapter 3.4.3
“Switching contacts“
)
.
(6) Mains connection
Mains connection is via a 2-pin WAGO (grounding screwed). The switching power supply (with Power
Factor Correction) allows a supply voltage of 100 V
–
240 V AC / 4 A / 50/60 Hz.
WAGO terminal for mains connection with two pins (1) and (3) and grounding screw (2)