12
REDNET D16/D16R OPERATION
First Use and Firmware Updates
Your RedNet D16/D16R may require a firmware update* when it is first installed and switched on.
Firmware updates are initiated and handled automatically by the RedNet Control application.
*It is important that the firmware update procedure is not interrupted – either by switching off power to the
RedNet D16/D16R unit or the computer on which RedNet Control is running, or by disconnecting either from
the network.
From time to time Focusrite will release RedNet firmware updates within new versions of RedNet
Control. We recommend keeping all RedNet units up to date with the latest firmware version supplied
with each new version of RedNet Control.
Digital Clocking
Each RedNet D16/D16R will automatically lock to a valid Network Master via its Dante connection.
Alternatively, If a Network Master is not present, then the unit can be chosen as the Network Master
by the user.
Pull Up and Pull Down Operation
RedNet D16/D16R is able to operate at a specified pull up or pull down percentage as selected in the
Dante Controller application.
Sample Rate Converters
SRC will need to be switched in for any sources that are not using the current system clock as a
reference signal.
SRC can be switched in or out separately for each input channel pair.
Note that engaging the sample rate converters will increase the overall latency of the device.