background image

9

11.  S/PDIF INPUT –  phono  socket  allowing  connection  of  the  S/PDIF  output  of  a  digital  audio 

device. The two channels connected here may be placed on the RedNet network, as selected 

in RedNet Control. The S/PDIF signal connected here may also be used as the unit’s sync 

source.

12.  WORD CLOCK INPUT – a BNC socket for the connection of a dedicated word clock sync signal, 

typically derived from a studio master clock source used to sync all the interconnected digital 

audio units in the system.

13.  WORD  CLOCK  OUTPUT  –  a  BNC  socket  from  which  a  word  clock  signal  may  be  obtained 

for connection to other digital audio devices outside the RedNet network. The clock signal 

available here will be derived from the source selected in software, and confirmed on the 

RedNet 3’s front panel by LED.

14.  ETHERNET – RJ45 network socket. Use a standard computer network cable to connect this 

socket to a local Ethernet switch to connect the RedNet 3 to the RedNet network. The socket 

has  integral  LEDs  which  illuminate  to  indicate  connection  to  an  active  network  port,  and 

network activity.  See page 13 for connector details.

15.  AC mains inlet – standard IEC receptacle for connection of AC mains. RedNet 3 has a ‘Universal’ 

PSU, enabling it to operate from any supply voltages between 100 V and 240 V.

Содержание RedNet 3

Страница 1: ...User Guide www focusrite com FA0771 02...

Страница 2: ...the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over...

Страница 3: ...s RoHS as well as the following sections of California law which refer to RoHS namely sections 25214 10 25214 10 2 and 58012 Health and Safety Code Section 42475 2 Public Resources Code For Canada To...

Страница 4: ...tures 7 RedNet 3 Front Panel 7 RedNet 3 Rear Panel 8 Physical Characteristics 10 Power Requirements 10 Other RedNet system components 11 Using RedNet Control 11 Appendix 12 Connector Pinouts 12 Perfor...

Страница 5: ...h carry 8 audio channels at 44 1 or 48 kHz Outputs 5 to 8 duplicate the lower numbered ports at these sample rates At higher sample rates Inputs 5 to 8 and Outputs 5 to 8 are used for the higher numbe...

Страница 6: ...r Guide so that you are fully aware of all the possibilities that RedNet and its software has to offer If either User Guide does not provide the information you need be sure to consult www focusrite c...

Страница 7: ...rmat is present at the corresponding input or output TOSLINK port Note that as one port input or output can carry 8 channels of audio at a sample rate of 44 1 or 48 kHz but correspondingly less at hig...

Страница 8: ...ly to internal sync The selected clock internal or external is available at a Word Clock Output connector for connection to other digital audio devices outside the RedNet network RedNet 3 Rear Panel 8...

Страница 9: ...word clock signal may be obtained for connection to other digital audio devices outside the RedNet network The clock signal available here will be derived from the source selected in software and con...

Страница 10: ...C Ventilation is via slots in the enclosure at both sides Do not mount RedNet 3 immediately above any other equipment which generates significant heat for example a power amplifier Also ensure that w...

Страница 11: ...s 1 to 8 are always available at the AES EBU connector as well as the ADAT port Tools menu six options are offered Clock Source lets the user select the source of clock sync The options available are...

Страница 12: ...U Ch B output hot 17 AES EBU Ch B output cold 5 AES EBU Ch B output screen 18 AES EBU Ch A output hot 6 AES EBU Ch A output cold 19 AES EBU Ch A output screen 7 AES EBU Ch D input hot 20 AES EBU Ch D...

Страница 13: ...Blue 6 Green 7 White Brown 8 Brown Word Clock I O Ext sync Connector type 2 x 75 ohm BNC sockets Applies to WORD CLOCK INPUT and OUTPUT S PDIF I O Digital audio Chs 1 and 2 Connector type 2 x phono RC...

Страница 14: ...S EBU connector See Inputs ADAT outputs 32 channels 44 1 48 88 2 96 kHz sample rate 16 channels 192 kHz ADAT connectors TOSLINK lightguides x 8 S PDIF output 2 channels sync locked to RedNet system sa...

Страница 15: ...e warranty obligations are fulfilled by the distributor responsible for the country in which you purchased the product In the event that you need to contact the distributor regarding a warranty issue...

Страница 16: ...rt and Unit Servicing You can contact Focusrite Customer Support at Email supportteam focusrite com Phone UK 44 0 1494 462246 Phone USA 1 310 322 5500 Troubleshooting If you are experiencing problems...

Отзывы: