• Clearances to walls:
CAUTION: THE DISTANCE TO A COMBUSTIBLE WALL MUST BE
MAINTAINED AT 36 inches. PROPERTY DAMAGE OR DEATH CAN
OCCUR IF THIS DISTANCE IS NOT MAINTAINED. DRYWALL PRODUCTS
LINED WITH PAPER SUCH AS SHEETROCK ARE COMBUSTIBLE.
CLEARANCES AS INDICATED FURTHER APPLY.
Important - manufacturer specifications:
-
When placed close to a non-combustible wall leave a minimum of
8"
for
proper ventilation. To avoid premature aging of your painted walls, only
use mineral paint. With other paints, above clearances apply.
-
Fire clearance to glass (from hearth):
31-1/2".
-
Fire clearance to vinyl windows: refer to window technical
specifications.
CLEARANCES MAY ONLY BE REDUCED BY MEANS APPROVED BY THE
REGULATORY AUTHORITY.